Safety
Warning!
Hazardous Voltage: Can shock, burn, or cause death.
6
Disconnect power at the main panel before connecting the electrical
power supply to the reclaim unit panel or working on electrical
connections.
6
Ground the reclaim unit before connecting to the electrical power supply.
Failure to ground the reclaim unit can cause a severe or fatal electrical
shock hazard.
Step 1: Install, ground, wire and maintain the reclaim unit in accordance
with local electrical codes and ordinances that apply. Consult with local
building inspector for local code information.
Step 2: Ground the reclaim unit permanently using a wire of size and type
specified by local or National Electrical Code.
Do not ground to a gas supply line!
Step 3: Connect ground wire first. Connect to ground first, then to green
grounding terminal provided. Do not connect the reclaim unit power supply
until the unit is permanently grounded; otherwise serious or fatal electrical
shock hazard may be caused.
6
Do not connect the 3-Phase reclaim power leads to a 1-Phase power
supply. Do not connect the 1-Phase reclaim power leads to a 3-Phase
power supply.
6
The supply voltage must be within ±10% of the designated reclaim unit
voltage as shown on “Installation & Operating Instructions” label on
the electrical panel cover. Incorrect voltage can cause fire or seriously
damage reclaim unit and voids warranty. If in doubt consult a licensed
electrician.
Caution! This Reclaim Unit has been evaluated for use
with water only.