Enter Setup
169
** Exit Setup
Programming with Serial Commands
A data format can also be created by serial commands (HEX) sent from the host device.
All commands must be entered
in uppercase letters
.
The syntax consists of the following elements:
Prefix:
“~<SOH>0000” (HEX:
7E 01 30 30 30 30
), 6 characters.
Storage type:
“
@
” (HEX:
40
) or “#” (HEX:
23
), 1 character. “
@
” means permanent setting which will not be lost by
removing power from the scanner or rebooting it; “#” means temporary setting which will be lost by removing power from
the scanner or rebooting it.
Add Data Format Command:
“DFMSET” (HEX:
44 46 4D 53 45 54
), 6 character.
Data format:
“0” (HEX:
30
) or “1” (HEX:
31
) or “2” (HEX:
32
) or ”3” (HEX:
33
), 1 character. “0”, “1”, “2” and “3” represent
Format_0, Format_1, Format_2 and Format_3 respectively.
Formatter command type:
“6” (HEX:
36
), 1 character.
Interface type:
“999” (HEX:
39
39
39
), 3 characters.
Symbology ID Number:
The ID number of the symbology to which you want to apply the data format, 3 characters. 999
indicates all symbologies.
Data length:
The length of data that will be acceptable for this symbology, 4 characters. 9999 indicates all lengths. For
example, 32 characters should be entered as 0032.
Formatter commands:
The command string used to edit data, max. 116 characters. For more information, see the
“Formatter Command Type 6” section in this chapter.
Suffix:
“;<ETX>” (HEX:
3B
03
), 2 characters.
Example:
Program format_0 using formatter command type 6, Code 128 containing 10 characters applicable, send all
characters followed by “A”.
Enter:
7E 01 30 30 30 30 40 44 46 4D 53 45 54 30 36 39 39 39 30 30 33 39 39 39 39 46 31 34 31 3B 03
(~<SOH>0000@DFMSET069990020010F141;<ETX>)
Response:
02 01 30 30 30 30 40 44 46 4D 53 45 54 30 36 39 39 39 30 30 33 39 39 39 39 46 31 34 31 06 3B 03
(<STX><SOH>0000#@DFMSET069990020010F141<ACK>;<ETX>)
Summary of Contents for HR42 Halibut
Page 1: ...HR42 Halibut Handheld Barcode Scanner User Guide...
Page 3: ...Revision History Version Description Date V1 0 0 Initial release May 27 2017...
Page 14: ......
Page 23: ...9 Dimensions Left View Front View...
Page 24: ...10 Top View...
Page 32: ...Enter Setup Exit Setup 18 Illumination On Off Aiming On Off Always On...
Page 172: ...Enter Setup Exit Setup 158 6 Scan the Exit Setup barcode...
Page 198: ...Enter Setup Exit Setup 184...
Page 201: ...187 Appendix Digit Barcodes 0 9 0 1 2 3 4 5 6 7 8 9...
Page 202: ...188 A F A B C D E F...