NTI SERIMUX SERIES SSH CONSOLE SWITCH
71
Appendix A - SERIMUX Port Characteristics
Every port is defined through the following parameters:
Description
Acceptable Value
Default Value
Number
1-4/8/16/24/32
Same (not changeable)
Name
Up to 50 characters
“Port00” to “Port32”
Type
User or Host
Host
Baud rate– Console port
50-115200
115200
Baud rate – except Console port
50-115200
9600
Data bits per character – Console port
8
8
Data bits per character – except Console
port
5,6,7,8
8
Stop bits
1, 2
1
Parity
No parity, even, odd
No parity
Flow control
Xon / Xoff (or in-band, or software),
RTS/CTS (or out-band or hardware),
Both,
None
None
Inter-character delay
1-60 milliseconds, none
None
break duration (added to 1 character
transmission time)
No break transmitted, 1-999 milliseconds
No break transmitted
Port escape sequence
ASCII characters
z
Connection timeout
0-99 minutes, (0=never)
15 minutes
DTR output upon disconnect
Low or high
High
Modem Reset string
Up to 41 characters
ATZ
Modem Initialization string
Up to 41 characters
AT&F&C1&D2S0=0
Modem Disconnect string
Up to 41 characters
ATH
Appendix B-SERIMUX User and Administrator Characteristics
The users and the administrator are defined through the following parameters:
Description
Acceptable Value
Default Value
Users:
User name
Up to 50 characters – case sensitive
None (must provide
name)
User password
Up to 50 characters – case sensitive
“” (empty string)
Position at Login
Port Connect,Config menu, Shell
Port Connect
Group
Admin or User
User
Administrator:
Administrator name
“root” – case sensitive
Same (not changeable)
Administrator password
Up to 50 characters – case sensitive
“nti”
Login timeout
0-999 minutes (0=never)
15 minutes