NTI SERIMUX SERIES SSH CONSOLE SWITCH
58
Unit Settings->Date and Time Settings
Figure 91- Unit Settings page, date and time
The Date and Time of the SERIMUX (
Administrative Settings->Unit Settings->Date & Time Settings
) can be either manually
setup to use an onboard clock or set to be synchronized with an NTP server.
To synchronize it, change the “Enable NTP” value from “Disable” to “Enable”. Enter appropriate values for
•
IP address of the NTP Server
•
Frequency (how often, in hours (0-99), the SERIMUX will query the NTP Server)
•
time zone for the location of the SERIMUX.
To set it manually, set the “Enable NTP” value to “Disable”. Enter the
•
date in mm/dd/yyyy format
•
time in 24 hour format hh:mm:ss .
•
time zone for the location of the SERIMUX
•
the UTC offset from GMT (if you are located in GMT, the value is “00.00”)
The UTC offset value is hh.mm (hours.minutes). If you are behind GMT, the value will be negative (i.e. “-02.00”). If you are
ahead of GMT, the value will be positive (i.e. “+02.00” or “02.00”).
In order to have the time change in accordance Daylight Saving Time rules, set the value of “Daylight Saving Enable” to “Enable”.
and select the appropriate time zone in the “Daylight Time zone” box. Also be sure to apply proper Start Date/Time and End
Date/Time values for when Daylight Saving Time begins and ends.
Be sure to press “
Save
” to have the changes take effect after the next reboot of the SERIMUX, or “
Save & Apply
” to have the
change take effect immediately.