Further documentation 

10.3.1  Address conversion table 

The following table is a parameterization aid for fining the correct setting for 
rack/slot or for remote TSAP in addressed mode. 

 

Bus 
addr. 

Rack 

Slot 

TSAP 

 

Bus 
addr. 

Rack 

Slot 

TSAP 

 

Bus 
addr. 

Rack 

Slot 

TSAP 

 

Bus 
addr. 

Rack 

Slot 

TSAP 

0200 

 

32 

0220 

 

64 

0240 

 

96 

0260 

0201 

 

33 

0221 

 

65 

0241 

 

97 

0261 

0202 

 

34 

0222 

 

66 

0242 

 

98 

0262 

0203 

 

35 

0223 

 

67 

0243 

 

99 

0263 

0204 

 

36 

0224 

 

68 

0244 

 

100 

0264 

0205 

 

37 

0225 

 

69 

0245 

 

101 

0265 

0206 

 

38 

0226 

 

70 

0246 

 

102 

0266 

0207 

 

39 

0227 

 

71 

0247 

 

103 

0267 

0208 

 

40 

0228 

 

72 

0248 

 

104 

0268 

0209 

 

41 

0229 

 

73 

0249 

 

105 

0269 

10 

10 

020A 

 

42 

10 

022A 

 

74 

10 

024A 

 

106 

10 

026A 

11 

11 

020B 

 

43 

11 

022B 

 

75 

11 

024B 

 

107 

11 

026B 

12 

12 

020C 

 

44 

12 

022C 

 

76 

12 

024C 

 

108 

12 

026C 

13 

13 

020D 

 

45 

13 

022D 

 

77 

13 

024D 

 

109 

13 

026D 

14 

14 

020E 

 

46 

14 

022E 

 

78 

14 

024E 

 

110 

14 

026E 

15 

15 

020F 

 

47 

15 

022F 

 

79 

15 

024F 

 

111 

15 

026F 

16 

16 

0210 

 

48 

16 

0230 

 

80 

16 

0250 

 

112 

16 

0270 

17 

17 

0211 

 

49 

17 

0231 

 

81 

17 

0251 

 

113 

17 

0271 

18 

18 

0212 

 

50 

18 

0232 

 

82 

18 

0252 

 

114 

18 

0272 

19 

19 

0213 

 

51 

19 

0233 

 

83 

19 

0253 

 

115 

19 

0273 

20 

20 

0214 

 

52 

20 

0234 

 

84 

20 

0254 

 

116 

20 

0274 

21 

21 

0215 

 

53 

21 

0235 

 

85 

21 

0255 

 

117 

21 

0275 

22 

22 

0216 

 

54 

22 

0236 

 

86 

22 

0256 

 

118 

22 

0276 

23 

23 

0217 

 

55 

23 

0237 

 

87 

23 

0257 

 

119 

23 

0277 

24 

24 

0218 

 

56 

24 

0238 

 

88 

24 

0258 

 

120 

24 

0278 

25 

25 

0219 

 

57 

25 

0239 

 

89 

25 

0259 

 

121 

25 

0279 

26 

26 

021A 

 

58 

26 

023A 

 

90 

26 

025A 

 

122 

26 

027A 

27 

27 

021B 

 

59 

27 

023B 

 

91 

27 

025B 

 

123 

27 

027B 

28 

28 

021C 

 

60 

28 

023C 

 

92 

28 

025C 

 

124 

28 

027C 

29 

29 

021E 

 

61 

29 

023D 

 

93 

29 

025D 

 

125 

29 

027D 

30 

30 

021F 

 

62 

30 

023E 

 

94 

30 

025E 

 

 

 

 

 

31 

31 

0220 

 

63 

31 

023F 

 

95 

31 

025F 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PRO ETH

Page 1: ...Reitzner Allee 6 D 85540 Haar Tel 49 89 4 56 56 340 Fax 49 89 4 56 56 399 info automation softing com www softing com Ethernet Gateway for MPI PROFIBUS User Manual Edition 5 2007 07 18 HW 1 1a 1 and...

Page 2: ......

Page 3: ...of a utility model or design Copyright 2007 by Softing AG Richard Reitzner Allee 6 D 85540 Haar Note We have checked the content of this manual for conformity with the hardware and software described...

Page 4: ......

Page 5: ...7 3 5 2 Other accessories 7 4 Installation of the driver software 8 4 1 Introduction 8 4 2 System requirements 8 4 3 Running the installation setup 8 4 3 1 Adding the interface to the PG PC interface...

Page 6: ...essing rack slot mode ON OFF 36 8 2 Example of configuration for WinCC V6 0 38 8 2 1 Using addressed mode 38 8 2 2 Use of rack slot mode 41 9 Troubleshooting 44 10 Appendix 49 10 1 Technical data 49 1...

Page 7: ...and accident prevention regulations applicable to the application in question During configuration safety and accident prevention rules specific to the application must be observed Emergency OFF faci...

Page 8: ...7 400 programmable controller from Siemens The NETLink PRO ETH is for use within a complete system only For that reason the configuring engineer user and installing technician must observe the standar...

Page 9: ...the NETLink PRO ETH without having to remove other system components there is enough space to connect existing interfaces and other contacts using standard commercial type accessories there is room fo...

Page 10: ...be used by the other protocol On both the TCP and the field bus sides the baudrate used can be determined automatically autonegotiation or autobaud The NETLink PRO ETH can draw the necessary power sup...

Page 11: ...onnector Bus connector with programming unit socket switchable terminating resistor and 1 2 m connecting cable The programming unit socket of the bus connector allows further bus nodes to be plugged i...

Page 12: ...PRO ETH indicate the operating status of the device itself LED status for operating status Power LED green Active LED green Active LED red Connect LED green Connect LED red Search for TCP configuratio...

Page 13: ...ounting rail bracket for NETLink PRO ETH Order code RS232 MPI HS The DIN rail bracket is for mounting the NETLink PRO ETH on a DIN standard mounting rails The DIN rail bracket and NETLink PRO ETH can...

Page 14: ...ention to the requirements of the SIMATIC package used A functioning network link using TCP IP must have been set up on the PCs that are used The network configuration of the PC must be known You can...

Page 15: ...O ETH from the left hand list click the Install button The following query then appears If you answer Yes to this query the NETLink PRO ETH is immediately set as the current access path If you respond...

Page 16: ...losed 4 3 2 Selecting the required interface parameterization The selection list for the interface parameter sets now contains an additional three items for the NETLink PRO ETH All relevant settings o...

Page 17: ...the programmable controller will be established The NETLink PRO ETH hardware can also be parameterized in this window Bus settings Here it is possible to state the bus configuration e g station addre...

Page 18: ...3 If the NETLink PRO ETH is configured via the NETLink PRO driver the following points must be considered If the NETLink PRO ETH is active on the bus when reparameterization is required e g a variabl...

Page 19: ...asier assignment Is the desired NETLink PRO ETH behind a router e g internet teleservice the network administrator is able to configure the router via NAT PAT So all frames going to a specific port of...

Page 20: ...ollowing dialog box will appear again This station can also be saved with OK and is then available If you do not want the name that is stored in the NETLink PRO ETH to be the same as the station name...

Page 21: ...ametrize NETLink PRO ETH button takes you to a new input form that already contains the current parameters of the NETLink PRO ETH If no NETLink PRO ETH can be accessed via the stated IP address the fo...

Page 22: ...that the device is accessible in the network and can be reparameterized if necessary Times shorter than 30 seconds are replaced by the default value 30 seconds because most DHCP servers require 12 to...

Page 23: ...involved There are various ways of implementing teleservice via a WAN wide area network Here are some suggestions Assignment of a separate unique IP address with direct access to the network Advantage...

Page 24: ...ble controller Usually this functionality is not available at S7 200 systems CPUs still exist usually older types that do not support cyclic distribution of bus parameters The autobaud functionality c...

Page 25: ...ers is possible Use of the autobaud function does not impair the functionality but initialization of a connection takes longer because the online parameters have to be ascertained Some older Siemens C...

Page 26: ...n address mentioned in section 5 1 2 1 PROFIBUS also has parameter field for selecting the bus profile and bus parameters Profile Under PROFIBUS there are usually the profiles DP Standard und User def...

Page 27: ...ascertains the bus parameters Under PROFIBUS please note that the autobaud function can only be used if the Cyclic distribution of the bus parameters function is activated in the programmable controll...

Page 28: ...ition to the parameters transmission rate and highest station address mentioned in Section 5 1 2 1 PPI also has parameter field for selecting advanced PPI As actually known all S7 200 cpus of the prod...

Page 29: ...all driver files are listed here If support is needed this data is used to obtain information about the components used quickly and effectively 5 2 Diagnostics For rudimentary diagnostics of the conn...

Page 30: ...sible a list of all bus parameters will be displayed by clicking the button Read The possibility to detect the bus parameters depends on the parameterization of the PG PC Interface It is recommended t...

Page 31: ...c used for parameterization it is possible to configure the NETLink PRO ETH via the integrated web interface s 7 3 If you have the S7 S5 OPC Server configurator available you can use the scan function...

Page 32: ...he user intuitively with information and configuration tasks 7 1 Home page The home page which is located at http ip address is a basic address and navigation starting point for the user From this pag...

Page 33: ...sible connections etc and specific information baud rate active stations DHCP status etc that could be useful when troubleshooting Device specific parameters Product name NETLink PRO ETH Product order...

Page 34: ...nnections will be displayed TCP specific parameters IP address The currently used IP address of the NETLink PRO ETH is shown e g 192 168 4 49 Subnet mask The currently used subnet mask of the NETLink...

Page 35: ...ther R S mode ON or addressed mode OFF is used for details see 8 1 4 Fixed destination address for R S mode If R S mode is activated all incoming RFC1006 requests are routed to the bus address paramet...

Page 36: ...ction 8 Device specific parameters Device name Name consisting of max 20 alphanumeric characters TCP parameters Static IP address IP address that is used if DHCP is deactivated or the DHCP timeout ela...

Page 37: ...tered a second time After you have entered changes clicking the Cancel button will discard your changes again If you click the OK button the inputs are checked for plausibility You may then be shown w...

Page 38: ...face Using PPI MPI or PROFIBUS functionalities are not possible Also the configuration tool is not working Parameters of the TCP access list TCP access list ON OFF Switch ON OFF the functionality of t...

Page 39: ...lick the OK button again After the new parameterization data have been stored the NETLink PRO is restarted to activate the new configuration It is also possible to reboot the NETLink PRO ETH remotely...

Page 40: ...to the NETLink PRO ETH The following software packages with RFC1006 support have so far been tested in conjunction with the NETLink PRO ETH WinCC V6 0 Siemens AG ZenOn V6 2 COPA DATA PROCON Win V3 2 G...

Page 41: ...station address The Own station address option indicates the bus address with which the NETLink PRO ETH will log on to the bus The value for the station address must have any value in the range 0 thr...

Page 42: ...alue should be read from the PROFIBUS project Retry This value is always 2 for MPI whatever the baudrate For PROFIBUS the appropriate value should be read from the PROFIBUS project Please note that un...

Page 43: ...address 2 the following has to be entered Rack 0 Slot 2 If you want to communicate with destination address 49 on the other hand the following has to be set Rack 1 Slot 17 Section 10 3 1 contains a ta...

Page 44: ...xplains addressed mode using WinCC as an example 8 2 Example of configuration for WinCC V6 0 The basic parameterization of RFC1006 connections in visualization systems is explained here using the exam...

Page 45: ...the IP address 192 168 4 49 The destination CPU with which we want to communicate has the PROFIBUS address 49 Because addressed mode is to be used we can read off the correct value for the rack and sl...

Page 46: ...was named MB0_over_NETLink_PRO in this case we can now select the type of variable by clicking the Select button Marker byte 0 is configured here The following screenshot shows that a variable named...

Page 47: ...can of course be created and used according to the same scheme It is also possible to create additional TCP IP connections in order to communicate not only with the CPU with bus address 49 but also wi...

Page 48: ...the real values for rack and slot are specified in this case rack 0 and slot 2 Please note that the destination address 49 in this case must now be announced to the NETLink PRO ETH via the Web interf...

Page 49: ...n will be established to the CPU with address 49 via the NETLink PRO ETH to read or write marker byte 0 from this rack 0 slot 2 Further variables of different types can of course be created and used a...

Page 50: ...RO ETH directly to my PC notebook but it doesn t work A A direct connection between two NIC network interface card interfaces is not possible You need a cross over adaptor Order no NETLINK CROSS or a...

Page 51: ...known as S7 TCP IP port 102 must also be released Attention If you want to use the driver option Internet teleservice see chapter 5 1 1 1 the specific ports configured there must be released also beca...

Page 52: ...possible A If possible use the autobaud functionality If this is not possible or not desired check the timing parameters for the PROFIBUS in the STEP7 configuration Enter the read values into the adv...

Page 53: ...itted too infrequently and cannot be detected by the NETLink PRO Please deactivate the autobaud functionality in the NETLink PRO driver PG PC interface and set the correct baudrate and the correct pro...

Page 54: ...rack field consists of three bits and the slot field of five bits i e together they comprise one byte and eight bits That means for example the value 1 00000001Bin 01Hex in the rack field must be ent...

Page 55: ...n SUB D connector 9 way with programming unit interface and terminating resistor MPI PROFIBUS protocols FDL protocol for MPI and PROFIBUS Displays 3 LEDs including 2 two color LEDs for general status...

Page 56: ...2 TX transmit data 3 RX receive data 4 unused 5 unused 6 RX receive data 7 unused 8 unused The NETLink PRO ETH comes with a shielded category 5 TCP cable with a length of three meters The maximum cabl...

Page 57: ...5 2 11 024B 107 3 11 026B 12 0 12 020C 44 1 12 022C 76 2 12 024C 108 3 12 026C 13 0 13 020D 45 1 13 022D 77 2 13 024D 109 3 13 026D 14 0 14 020E 46 1 14 022E 78 2 14 024E 110 3 14 026E 15 0 15 020F 47...

Page 58: ...52 NETLink PRO ETH 10 3 2 Information in the Internet http www softing com http www profibus com http www siemens com http www ietf org rfc...

Page 59: ......

Reviews: