Nuvo-8108GC
86
Mode 3 ~ Mode 12
Mode 3 ~ Mode 12 have various power-on delay and power-off delay. Each mode
supports a hard-off timeout of 10 minutes.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
3
10 seconds
10 seconds
10 minutes
4
10 seconds
1 minute
10 minutes
5
10 seconds
5 minutes
10 minutes
6
30 seconds
1 minute
10 minutes
7
30 seconds
5 minutes
10 minutes
8
30 seconds
10 minutes
10 minutes
9
3 minutes
1 minute
10 minutes
10 (A)
3 minutes
10 minutes
10 minutes
11 (B)
3 minutes
30 minutes
10 minutes
12 (C)
10 minutes
30 minutes
10 minutes
Mode 13 (D) / Mode 14 (E)
Mode 13 and Mode 14 are ignition power control modes with very long power-off delay.
Both modes support the feature of “smart off-delay”, which automatically detect system
status during power-off delay duration and cut off system power if system is off in prior to
power-off delay expired.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
13 (D)
30 seconds
2 hours
10 minutes
14 (E)
3 minutes
2 hours
10 minutes
Summary of Contents for Nuvo-8108GC Series
Page 1: ...Neousys Technology Inc Nuvo 8108GC Series User Manual Revision 1 2 ...
Page 14: ...Nuvo 8108GC 14 1 2 2 Nuvo 8108GC Ignition Dual 4 Pin Terminal Block Panel View ...
Page 15: ...Nuvo 8108GC 15 1 2 3 Nuvo 8108GC Top Panel View 1 2 4 Nuvo 8108GC Heatsink Panel View ...
Page 16: ...Nuvo 8108GC 16 1 2 5 Nuvo 8108GC Bottom View 1 2 6 Nuvo 8108GC Wall mount Dimension ...
Page 77: ...Nuvo 8108GC 77 2 Place the system on a flat surface and secure it with screws ...
Page 132: ...Nuvo 8108GC 132 7 Follow the 6 step setup procedure as instructed ...
Page 134: ...Nuvo 8108GC 134 9 When done click on Finish and restart the system ...