5 NEMTEK Ethernet Module Setup C
10
c. Ensure that all
“ModuleStaticIP”
addresses are in the same IP range. This
means that for the range mentioned in (b.), the first 3 numbers (e.g. 192.168.0)
of the
“ModuleStaticIP”
address must be exactly the same for all network
devices and the last number may range from 1 to 254. An example of valid
“ModuleStaticIP”
addresses on the same network will be:
i. NEMTEK NemLink (connected to NEMTEK FG7): 192.168.0.150
ii. NEMTEK NemLink (connected to Energizer): 192.168.0.100
iii. NEMTEK 8-way Relay Board: 192.168.0.55
iv. NEMTEK Smart IO Board: 192.168.0.200
14. Enter a new
“RemoteIP”
adhering to the following criteria:
a. The NemLink connected to the FG7, must have a
“Remote IP”
address where
the first three numbers are exactly the same as the first three numbers of all
the devices on the network and the last number is 255.
b. The NEMTEK Smart IO Board can only communicate with one energizer,
therefore the
“RemoteIP”
must be identical to the
“ModuleStaticIP”
of the
energizer it communicates with.
c. With reference to the
“ModuleStaticIP”
addresses in the example in step 13,
the following is an example of valid
“RemoteIP”
addresses on the same network:
i. NEMTEK NemLink (connected to NEMTEK FG7): 192.168.0.255
ii. NEMTEK NemLink (connected to Energizer): not required
iii. NEMTEK 8-way Relay Board: not required
iv. NEMTEK Smart IO card: 192.168.0.100
15. Click on
“Save Config”
to change the parameters on the module.
“ACK”
will appear
three times in the lower left dialog box if the changes were successful.
16. To check that the settings were saved successfully, click on the
“Search Device”
button again. The changed network device IP address should appear in the dialog
box above the
“Search Device”
button. Click on this device and ensure that all
parameters were changed correctly.
17. Remove the jumper as mentioned in step 2 for the Taut Wire Node, NemLink and
Nemlink Network IO boards. Install the jumper on the 2 lower pins for the 8-way
Relay Board and 8-way Smart IO Board.
18. The network device is now ready for installation.