Stud welding unit N1500i
As of: June 06.2012
Manual part number: BE 1221
87
Tucker GmbH,
Mail / Post:
Max-Eyth-Str.1, 35394 Gießen, Germany
F
code
Description
Possible Values
Default
Unit
Notes
F19 Lock Mode
1 to 3
1
x
Mode 1: Use the lock key to toggle blocking on all keys - no
password protec- tion. Mode 2:
Use the lock key to enter a password, lock key as ‘enter’. From
there, all keys are blocked until you press lock again. It will prompt
for the same password entered when originally locked. Pass-
word can be up to 9 characters. Mode 3: Same as mode 2, except
user can tog- gle between presets and cannot change the value of
presets. Mode 4: Same as mode 3 except the user can adjust the
time and current by a percentage as set by F57.
F20 Debug
ENTER DEBUG
MODE
ENTER
DEBUG
MODE
x
Used by manufacturing and service.
F21 User Counter
0 to 4.3B
0
Welds
While in this F code, press and hold the time-down button 3-5
seconds to reset the counter.
F22 Total Counter
0 to 4.3B
0
Welds
(Non-resettable)
F23 Chuck Stripper
OFF ON
OFF
x