6.3.7 Weld Parameters and Settings
Note!
Weld parameters and settings below are developed using Nelson
equipment and Nelson studs. It is recommended to use fasteners
from one manufacturer (Nelson studs) to ensure weld consistency
and compatibility.
In order to make sure the reproducibility of welds only studs from one
batch may be used. Studs from different batches may not be mixed.
Factory Preset Weld Settings (Short Cycle)
Preset
Nelson Stud Type
Stud Size
∅
Current (Amps)
Time (ms)
P
res
et
B
ank
2
*
1
SC-Studs [3.0 M3]
4 mm
400
15
2
SC-Studs [4.0 M4]
5 mm
500
15
3
SC-Studs [5.0 M5]
6 mm
600
20
4
SC-Studs [6.0 M6]
7 mm
700
25
5
SC-Studs [6.0 M6]
7 mm
700
25
6
SC-Studs [6.0 M6]
7 mm
700
25
7
SC-Studs [6.0 M6]
7 mm
700
25
8
SC-Studs [6.0 M6]
7 mm
700
25
9
SC-Studs [6.0 M6]
7 mm
700
25
0
SC-Studs [6.0 M6]
7 mm
700
25
The duty cycle limits for the Nelweld N1500i can be seen in the Stud Weld Rate
table below. If the duty cycle is exceeded, and a weld is attempted, a “Wait” prompt
will be displayed. “Wait” will disappear when the unit is ready for another weld. If
the unit reaches an abnormally high temperature, a failsafe thermal sensor will
protect the unit and display E011. The unit will resume operation once the
temperature has returned to safe operating range.