3.1.8
Close Upper Slide Valve V12
The message appears when the TVFD Upper Solenoid Valve is expected to close. The
timer is set with TVFDC-Al, see Section
‘4.2.26 TVFD-Al-Tmr’
. If the timer elapses, the
‘TVFD Alarm! Upper Slide Not Closed is activated. This message is only shown when TVFD
advanced is activated.
ESC
OK
Close Upper
Slide Valve
Remaing
ti
me
08:00s
Remaining Time: The remaining time for the valve to close before the
alarm is activated.
3.1.9
Emptying bin TVFD Advanced
The message appears when the TVFD Lower Solenoid Valve is expected to open. The timer
is set with TVFDC-Al, see Section
‘4.2.26 TVFD-Al-Tmr’
. If the timer elapses, the ‘TVFD
Alarm! Lower Slide Not Open is activated. This message is shown when TVFD advanced is
activated. TVFD-Al is only activated when using TVFD advanced.
ESC
OK
EMPTYING BIN
Open Lower
Slide Valve
Remaing Time
02:00s
Remaining Time: The remaining time for the valve to open before the
alarm is activated.
3.1.10 Close Lower Slide Valve V11
The message appears when the TVFD Lower Solenoid Valve is expected to close. The
timer is set with TVFDC-Al, see Section
‘4.2.26 TVFD-Al-Tmr’
. If the timer elapses, the
‘TVFD Alarm! Lower Slide Not Closed is activated. This message is only shown when TVFD
advanced is activated.
ESC
OK
Close Lower
Slide Valve
Remaing time
05:00s
Remaining Time: The remaining time for the valve to close before the
alarm is activated.
3.1.11 Flushing duct
The unit is flushing the duct system. This message is shown when FlushCy1 and FlushCy2
activate the flush valve. This message is also shown when FlushTemp is activated, see
Sections
‘4.2.30 FlushCy1’, ‘4.2.22 FlushCy2’ and
‘4.2.24 FlushTmp’
.
ESC
OK
Flushing
Ducts
Cycl 1
03:00 s
Cycl 2
05:00 s
Cycl1: The time remaining for the flush cycle with the flush valve 1
(SFV1).
Cycl2: The time remaining for the flush cycle with the flush valve 2
(SFV2).