FlexPAK 800/1000
EN
14
3.2.2
Warning! Main Filter Clogged
This Warning is only shown when the Main Filter Delta Pressure Switch (MFDPS) is
installed. This message is displayed if the Differential Pressure switch “DP switch” is
installed and the Dp switch detects a high differential pressure across the filter.
When the Dp switch detects a high Dp pressure, it activates a timer, which is shown in the
display. If the Dp pressure is still high when the timer elapses, the vacuum unit will stop and
the alarm message “Alarm! Main Filter Clogged” is activated.
ESC
OK
Warning!
Main Filter Clogged
Th 11:23
Time to Unit
Stop 08:00 m
Reset OK
Time to Unit Stop: Displays the time until the unit is stopped.
3.2.3
Dustbin Full
The Bin Level Indicator has detected that the dust bin has been full for 12 minutes. Empty
the dust bin and press
OK
to reset the warning.
ESC
OK
Warning!
D u s t b i n F u l l
Th 15:01
Time To Unit
Stop 05:00 m
Reset OK
Time to Unit Stop: Displays the time until the unit is stopped.
3.2.4
Bag Replacement Switch Activated
The bag replacement switch (SC2) is activated. It shows the maximum allowed time to
replace the dust bag, and how much time is left to replace the dust bag and turn off the
bag replacement switch before the unit is put into Off mode.
If this warning is activated, the light in the Standby/Running button is lit for two seconds
and then again in 2 seconds. This 2/2 on/off sequence continues until the warning is reset.
ESC
OK
Bag Replacement
Switch Activated
Time to Unit
Stop
02:00m
Max Time 30:00m
Stop: The remaining time to replace the dust bag before the unit is put
into Off mode.
MaxTime: The maximum amount of time allowed to replace the dust
bag.
3.2.5
Warning Low Vacuum
Function to warn when the vacuum is too low in the system.
When the vacuum is too low, Vac_Low activates the delay timer (VacLoTm) function when
the message expires. When the vacuum rises above the set limit value, the message
disappears automatically.
The Vac_Low parameter default setting is -15kPa.
The VacLoTm parameter default setting is 1 minute.
ESC
OK
Warning Low
Vacuum
Limit
15kPa
Actual kPa 10kPa