FlexPAK 800/1000
21
EN
4.2
Parameter settings
4.2.1
Adjust the time and date
ESC
OK
Thu 10:45
2018-02-01
ESC
OK
FlexPak
Hi Vacuum Unit
OFF
Time To Service
2000 hours
ESC
OK
Stop
>
Program
>
Setup
>
Network
>
Diagnos
ti
cs
>
ESC
OK
Msg Con
fi
g
>
Start Screen
>
Clock
>
LCD
>
Menu Language
>
Switch to OP
ESC
OK
Set Clock
>
S/W
ti
me
>
Sync
>
Thu 10:45
2018-02-01
ESC
OK
Set Clock
Do the following to adjust the time and date:
1.
From the PLC status screen, press the down arrow to go to the date and time
screen.
2.
Press ‘Escape’
ESC
to go to the main menu.
3.
Pressthe down arrow to go to ‘Setup’. Press ‘OK’
OK
to confirm.
4.
Pressthe down arrow to go to ‘Clock’. Press ‘OK’
OK
to confirm.
5.
Pressthe down arrow to go to ‘Set Clock’. Press ‘OK’
OK
to confirm.
6.
Use the left and right arrows
to move to cursor to parameter value. Press ‘OK’
OK
to confirm.
7.
Use the up or down arrows
to set Time or Date. Press ‘OK’
OK
to confirm.
Weekday is automatically set by the date.
8.
Press ‘Escape’
ESC
3 times to go to the time screen.
9.
Press the up arrow to exit.
NOTE!
There are several other input menus on the same level as the date and time screen.
If pressing the down arrow takes the PLC to one of those menus, use the left arrow
to get to the date and time screen.