FlexPAK 800/1000
33
EN
4.2.38 BLI-Alarm
Menu for setting the delay time for the Bin Level Indicator Alarm message. When the BLI
signal disappears, the BLI-Alarm timer is activated. When the timer elapses, the Alarm
message “Alarm! Dustbin Full” appears and the vacuum unit is stopped.
ESC
OK
BLI-Alarm
1/1
T = 30:00m
Ta = 00:00m
T=30:00m: Time before Alarm! Dustbin Full message is activated. The
default is 30 minutes.
Ta=00:00: Elapsed time since the BLI-sensor was activated.
4.2.39 MFDPS-Al
Menu for setting the Main Filter Differential Pressure Sensor Alarm (MFDPS-Al) delay timer.
When the Main Filter Differential Pressure Sensor signal disappears, MFDPS-Al is activated.
When the delay timer has expired, the “Alarm! Main Filter Clogged” message is activated.
See Section
‘3.3.15 Alarm! Main Filter Clogged’.
When the timer has expired, the unit stops.
ESC
OK
MFDPS-Al
1/1
T = 20:00m
Ta = 00:00m
T=30:00m Time before MFDPS-Al is activated. The default is 30
minutes.
Ta=00:00 Elapsed time since the MFDPS signal disappeared.
4.2.40 DPFClean
Menu for activation and deactivation of DPFClean. When activated, this function causes the
Main Filter Differential Pressure to activate cleaning of the main filter.
When the setting for the maximum differential pressure has been exceeded, the Main Filter
Differential Pressure Sensor signal disappears and it cause MFDPS-FC to be activated, which
delays the start of the cleaning cycle. The delay is designed to filter away a temporarily high
differential pressure over the main filter. See Section
‘4.2.11 MFDPS-FC’
.
ESC
OK
DPFClean 1/1
Switch = Off
Switch=Off is the default setting; DPFClean is deactivated.
To activate DPFClean, set Switch=On.
4.2.41 EmtyIdli
Menu for activating automatic dust bin emptying when the unit goes into Idling Mode.
ESC
OK
EmtyIdli 1/1
Switch = Off
Switch=Off is the default setting. EmtyIdli is deactivated.
To activate EmtyIdli, set Switch=On.