1. Error Message
Express5800/R120d-1E, R120d-2E Maintenance Guide
144
Chapter 3 Appendix
Memory Mirroring Fail-over on CPU1
Memory Mirroring Fail-over on CPU2
[Description]
A correctable error frequently occurred on DIMM connected with CPUx, but Memory Mirroring feature failed
over to standby memory. x denotes CPU number.
You can continue to run the system.
[Recommended action]
Restart the server.
If it does not solve your problem, check installation status of DIMM.
If it does not solve your problem, remove DIMM and install it again.
If it does not resolve your problem, contact your sales representative.
Tips
•
You can identify the DIMM on which an uncorrectable error frequently
occurred by viewing OS system event log or IPMI system event log.
PCI1A Slot UnCorrectable Error
PCI1B Slot UnCorrectable Error
PCI2B Slot UnCorrectable Error
PCI3B Slot UnCorrectable Error
PCI1C Slot UnCorrectable Error
PCI2C Slot UnCorrectable Error
[Description]
An uncorrectable error occurred on PCIe bus on PCI board installed in slot PCIxx.
xx denotes PCI slot number.
[Recommended action]
Restart the server.
If it does not solve your problem, check installation status of DIMM.
If it does not solve your problem, remove DIMM and install it again.
If it does not resolve your problem, contact your sales representative.
PCI-Express Uncorrectable Error 1
[Description]
An uncorrectable error occured on PCIe bus of onboard LAN.
[Recommended action]
Restart the server.
If it does not resolve your problem, contact your sales representative.