1. Error Message
Express5800/R120d-1E, R120d-2E Maintenance Guide
128
Chapter 3 Appendix
[Recommended action]
Make sure the jumper switch setting on motherboard.
If it does not resolve your problem, contact your sales representative.
9001: Unsupported CPU detected on CPU #1
9002: Unsupported CPU detected on CPU #2
[Description]
An unsupported CPU was detected.
[Recommended action]
Try BIOS update again.
If it does not resolve your problem, contact your sales representative.
9060: Mismatched CPU Type detected
[Description]
CPU 1 and 2 are not the same type.
[Recommended action]
Two CPUs must be of the same type. Confirm CPU1 and CPU2.
If it does not resolve your problem, contact your sales representative.
9080: Link in Slow Speed Mode between CPU1 and CPU2.
[Description]
Low-speed mode was detected on bus between CPU1 and CPU2.
[Recommended action]
Restart the server.
If it does not resolve your problem, contact your sales representative.
9081: Link Failure between CPU1 and CPU2.
[Description]
Connection failure was detected on bus between CPU1 and CPU2.
[Recommended action]
Restart the server.
If it does not solve your problem, remove CPU2 and install it again.
If it does not solve your problem, remove CPU1 and install it again.
If it does not solve your problem, contact your sales representative.
When type of CPU1 differs from that of CPU2, this POST error may appear.
Two CPUs must be of the same type. Confirm CPU1 and CPU2.
9082: Link Width Error between CPU1 and CPU2.
[Description]