1. Error Message
Express5800/R120d-1E, R120d-2E Maintenance Guide
130
Chapter 3 Appendix
If it does not solve your problem, check installation status of DIMM.
If it does not solve your problem, remove DIMM and install it again.
If it does not solve your problem, contact your sales representative.
DIMMs are degraded in unit of a channel. For example, if CPU1_DIMM3 is degraded due to failure,
CPU1_DIMM6 is also degraded.
Connection
DIMM No.
CPU No.
Channel No.
CPU1_DIMM1 1
1
CPU1_DIMM2 1
2
CPU1_DIMM3 1
3
CPU1_DIMM4 1
1
CPU1_DIMM5 1
2
CPU1_DIMM6 1
3
CPU2_DIMM1 2
1
CPU2_DIMM2 2
2
CPU2_DIMM3 2
3
CPU2_DIMM4 2
1
CPU2_DIMM5
2 2
CPU2_DIMM6 2
3
AE81: CPU1_DIMM1 with error is enabled.
AE82: CPU1_DIMM2 with error is enabled.
AE83: CPU1_DIMM3 with error is enabled.
AE84: CPU1_DIMM4 with error is enabled.
AE85: CPU1_DIMM5 with error is enabled.
AE86: CPU1_DIMM6 with error is enabled.
AE87: CPU2_DIMM1 with error is enabled.
AE88: CPU2_DIMM2 with error is enabled.
AE89: CPU2_DIMM3 with error is enabled.
AE8A: CPU2_DIMM4 with error is enabled.
AE8B: CPU2_DIMM5 with error is enabled.
AE8C: CPU2_DIMM6 with error is enabled.
[Description]
A DIMM error was detected, but because all DIMMs are currently being degraded, this DIMM was forcibly
enabled.
CPUx_DIMMy denotes failed DIMM number.
[Recommended action]
Run SETUP, select
Advanced
→
Memory Configuration
→
Memory Retest
, and change parameter to
Yes
.
Then, select
Save & Exit
→
Save Changes and Exit
.
If it does not resolve your problem, contact your sales representative.
B000: Expansion ROM not initialized
B001: Expansion ROM not initialized - PCI Slot 1B
B002: Expansion ROM not initialized - PCI Slot 2B