CHAPTER 17 STANDBY FUNCTION
User’s Manual U15331EJ4V1UD
309
17.2 Standby Function Operation
17.2.1 HALT mode
(1) HALT
mode
The HALT mode is set by executing the HALT instruction.
The operation statuses in the HALT mode are shown in the following table.
Table 17-1. Operation Statuses in HALT Mode
HALT Mode Operation Status During Main
System Clock Operation
HALT Mode Operation Status During Subsystem
Clock Operation
Item
Subsystem Clock
Operating
Subsystem Clock
Stopped
Main System Clock
Operating
Main System Clock
Stopped
Clock generator
Oscillation enabled for both main system clock and subsystem clock, but clock supply to CPU is
stopped
Subsystem clock
×
4
multiplication circuit
Operation stopped
CPU Operation
stopped
Ports (output latches)
Status before HALT mode setting retained
16-bit timer 20
Operable
Operable
Note 1
8-bit timer 50
Operable
Operable
Note 2
8-bit timer 60
Operable
Operable
Note 3
8-bit timer 61
Operable
Operable
Note 3
Watch timer
Operable
Operable
Note 4
Operable
Operable
Note 5
Watchdog timer
Operable
Operation stopped
Key return circuit
Operable
Serial interface 20
Operable
Operable
Note 6
Serial interface 1A0
Operable
Operable
Note 6
LCD controller/driver
Operable
Note 7
Operable
Notes 4, 7
Operable
Note 7
Operable
Notes 5, 7
A/D converter
Operation stopped
Multiplier Operation
stopped
Remote controller
receiver
Note 8
Operable Operable
Note
4
Operable
Operable
Note 5
External interrupts
Operable
Note 9
Notes
1.
Operation is enabled when the 24-bit counter mode is selected.
2.
Operation is enabled when either the subsystem clock or the input signal from timer 60 (when timer 60
is operable) is selected as the count clock.
3.
Operation is enabled only when the external input clock is selected as the count clock.
4.
Operation is enabled when the main system clock is selected.
5.
Operation is enabled when the subsystem clock is selected.
6.
Operation is enabled only when an external clock is selected.
7.
The HALT instruction can be set after display instruction execution.
8.
µ
PD789489 and 78F9489 only.
9.
Operation is enabled only for a maskable interrupt that is not masked.