14.4 Multiplier Operation
The multiplier of the
µ
PD789489 Subseries can execute the calculation of 8 bits
×
8 bits = 16 bits. Figure 14-3
shows the operation timing of the multiplier where MRA0 is set to AAH and MRB0 is set to D3H.
<1> Counting is started by setting MULST0.
<2> The data generated by the selector is added to the data of MUL0 at each CPU clock, and the counter value
is incremented by one.
<3> If MULST0 is cleared when the counter value is 111B, the operation is stopped. At this time, MUL0 holds the
data.
<4> While MULST0 is low, the counter and slave are cleared.
Figure 14-3. Multiplier Operation Timing (Example of AAH
×
D3H)
AA
D3
000B
00AA
0000
001B
010B
011B
100B
101B
110B
111B
000B
0154
0000
0000
0AA0
0000
2A80
5500
00AA
00AA
01FE
01FE
01FE
0C9E
0C9E
371E
8C1E
00AA
01FE
01FE
01FE
0C9E
0C9E
371E
0000
CPU clock
MRA0
MRB0
MULST0
Counter
Selector output
MUL0
(Master)
(Slave)