73
2. RAID Levels
This section details the RAID levels that the disk array controller supports.
2-1 Characteristics of RAID Levels
The table below lists the characteristics of the RAID levels:
Level
Function
Redundancy
Characteristics
RAID0
Striping
No
Fastest data read/write
Largest capacity
Capacity: (capacity of single HDD) × (number of HDD
‟s)
RAID1
Mirroring
Yes
Two HDD
‟s required
Capacity: capacity of single HDD
2-2 RAID0
In RAID 0, data is distributed between HDD
‟s. This mode is called "striping."
In the figure below, data is recorded in stripe 1 (disk 0) and stripe 2 (disk 1). Because RAID0 allows HDD
‟s to
be accessed collectively, it can provide the best disk access performance.
Notice
RAID 0 does not provide data redundancy. If a HDD fails, the data saved
on the HDD cannot be recovered.
Disk array controller
HDD 0
Stripe 1
HDD 1
Stripe 3
Stripe 2
Stripe 4
Summary of Contents for N8403-019
Page 27: ...7 4 3 内部接続ケーブル 1本 4 4 ディスクアレイコントローラ取り付けネジ 3個 ...
Page 41: ...21 4 既存バックプレーンボードがある場合は 3箇所のネジを外し 既存バックプレーンボードを取 り外します 5 新規バックプレーンを 取り外した3箇所のネジを利用し取り付けます ...
Page 42: ...22 6 フロントカバーを コネクタの勘合に気を付けながら取り付けます 7 フロントカバーの両サイドのネジを取り付けます ...
Page 44: ...24 ケーブルを外す場合は ケーブルのロックピンを解除するため下図の場所を押しながら引き抜いて ください 10 リアカバーを取り付けます ...
Page 106: ...86 7 Install the rear cover ...
Page 111: ...91 When the adapter is selected in Adapter Selection the WebBIOS top menu appears ...
Page 113: ...93 Click Next to see the detailed settings of this controller ...