67
2. Specification
Item
Specification
Remarks
Number of SAS connectors
1 internal channel
2 ports per channel
Cache memory size
256 MB
Write policy of cache memory
Write Through
Write Back unsupported
Battery backup of cache memory
Unsupported
Write Through only
PCI bus
Conforming to PCI Express 1.0A
Mezzanine connector for blade
PCI Express (x8)
Mezzanine card slot
Type 2 only
Maximum PCI bus transfer rate
2.5 Gigabits/lane
HDD Device interface
SAS available
Maximum data transfer rate (SAS)
300 MB/sec
RAID level
0 or 1
Maximum number of disk array
controllers installed in server
1
Maximum number of connectable HDD
‟s 2
2 HDD
‟s connected per channel
Outer dimension (mm)
113 (width) x 135 (depth) x 22 (height)
Disk array controller
40 (width) x 102 (depth) x 39 (height)
Backplane
Weight
About 0.15 kg
Operating voltage
3.3V/12V
Power consumption (max.)
19.44W
3.3V/10.8A
12V/11.4A
Operating environment
Temperature: 10ºC to 35ºC
Humidity: 20% to 80%
No condensation
Summary of Contents for N8403-019
Page 27: ...7 4 3 内部接続ケーブル 1本 4 4 ディスクアレイコントローラ取り付けネジ 3個 ...
Page 41: ...21 4 既存バックプレーンボードがある場合は 3箇所のネジを外し 既存バックプレーンボードを取 り外します 5 新規バックプレーンを 取り外した3箇所のネジを利用し取り付けます ...
Page 42: ...22 6 フロントカバーを コネクタの勘合に気を付けながら取り付けます 7 フロントカバーの両サイドのネジを取り付けます ...
Page 44: ...24 ケーブルを外す場合は ケーブルのロックピンを解除するため下図の場所を押しながら引き抜いて ください 10 リアカバーを取り付けます ...
Page 106: ...86 7 Install the rear cover ...
Page 111: ...91 When the adapter is selected in Adapter Selection the WebBIOS top menu appears ...
Page 113: ...93 Click Next to see the detailed settings of this controller ...