125
(5) The following message is recorded in MSM log or Windows event log (application) when the OS
is started. In addition, the pop message appears if the notification to NEC ESMPRO Manager is
specified.
MSM log
Controller ID:x VD is now DEGRADED VDx.
Windows event log (application)
Source:
MR_MONITOR
Type:
Error
Event ID*
251
Description: Controller ID:x VD is now DEGRADED VDx.
The above message may appear at OS startup after the rebuild process has been performed
by WebBIOS. However, this is not a problem for normal system operation.
(6) HDD failed
Contact your service representative.
(7) Rebuild failed
□
Is the capacity of the HDD to be rebuilt smaller than the failed HDD?
Use a disk with the same capacity as the failed HDD.
□
Is the RAID level of the virtual disk RAID0?
Rebuild is not possible because RAID0 does not provide redundancy. Replace the failed
HDD and create the virtual disk again.
(8) Consistency Check failed
□
Is the virtual disk degraded?
→
Replace the failed HDD and execute rebuild.
□
Is the RAID level of the virtual disk RAID0?
→
Consistency Check is not possible because RAID0 does not provide redundancy.
(9) In installation of MegaRAID Storage Manager (MSM), [Security Warning] dialog appears when
installing the "Standby/Hibernation Lock (*1)" driver.
Select "Yes" in the message "Do you want to install this driver software?" to continue
installation.
*1
Displayed as "NEC Standby/Hibernation Lock" for the 64-bit OS.
Summary of Contents for N8403-019
Page 27: ...7 4 3 内部接続ケーブル 1本 4 4 ディスクアレイコントローラ取り付けネジ 3個 ...
Page 41: ...21 4 既存バックプレーンボードがある場合は 3箇所のネジを外し 既存バックプレーンボードを取 り外します 5 新規バックプレーンを 取り外した3箇所のネジを利用し取り付けます ...
Page 42: ...22 6 フロントカバーを コネクタの勘合に気を付けながら取り付けます 7 フロントカバーの両サイドのネジを取り付けます ...
Page 44: ...24 ケーブルを外す場合は ケーブルのロックピンを解除するため下図の場所を押しながら引き抜いて ください 10 リアカバーを取り付けます ...
Page 106: ...86 7 Install the rear cover ...
Page 111: ...91 When the adapter is selected in Adapter Selection the WebBIOS top menu appears ...
Page 113: ...93 Click Next to see the detailed settings of this controller ...