4. Replacement of Disk Array Controller
Replace the disk array controller in the following procedure:
Check
For the handling of the server, refer to the User
‟s Guide of the server.
CAUTION
Avoid installation in extreme temperature conditions.
Immediately after the server is powered off, its internal components such as HDD
‟s
are very hot. Leave the server until its internal components fully cool down before
installing/removing any component.
1.
Before connecting or disconnecting the disk array controller, be sure to remove the server from the
Blade Enclosure.
2.
Remove the side cover and several components on the server.
3.
Remove the internal cable from the disk array controller.
The internal cables are locked. Remove the cable while pushing the cable to unlock it.
4.
Remove the screws securing the disk array controller and remove it from the server.
5.
Insert a new disk array controller into the same Mezzanine card slot (Type 2) and secure it with the
screws.
6.
Connect all the cables removed in Step 3.
7.
Install the side cover and other components removed in Step 2 on the server.
8.
Connect the power cords to the receptacles and turn on the power of the server. Make sure that the
server boots normally.
Summary of Contents for N8403-019
Page 27: ...7 4 3 内部接続ケーブル 1本 4 4 ディスクアレイコントローラ取り付けネジ 3個 ...
Page 41: ...21 4 既存バックプレーンボードがある場合は 3箇所のネジを外し 既存バックプレーンボードを取 り外します 5 新規バックプレーンを 取り外した3箇所のネジを利用し取り付けます ...
Page 42: ...22 6 フロントカバーを コネクタの勘合に気を付けながら取り付けます 7 フロントカバーの両サイドのネジを取り付けます ...
Page 44: ...24 ケーブルを外す場合は ケーブルのロックピンを解除するため下図の場所を押しながら引き抜いて ください 10 リアカバーを取り付けます ...
Page 106: ...86 7 Install the rear cover ...
Page 111: ...91 When the adapter is selected in Adapter Selection the WebBIOS top menu appears ...
Page 113: ...93 Click Next to see the detailed settings of this controller ...