![NEC mPD780065 Series Preliminary User'S Manual Download Page 218](http://html.mh-extra.com/html/nec/mpd780065-series/mpd780065-series_preliminary-users-manual_249264218.webp)
218
CHAPTER 14 SERIAL INTERFACE (SIO1)
Preliminary User’s Manual U13420EJ2V0UM00
Notes 1. The interval time is 2/
fSCK
.
2. The data transfer interval time is calculated from the following expressions (n: Value set to ADTI00
to ADTI04).
<1> n = 0
Interval time =
2
+
0.5
f
SCK
f
SCK
<2> n = 1 to 31
Interval time =
n+1
+
0.5
f
SCK
f
SCK
Cautions
1. Do not write ADTI0 during operation of automatic data transmit/receive function.
2. Be sure to set bits 5 and 6 to 0.
3. When controlling the interval time of automatic transmit/receive data transfer by using
ADTI0, busy control is invalid. (Refer to 14.4.3 (4) (a) Busy control option.)
Remark
f
X
:
Main system clock oscillation frequency
f
SCK
: Serial clock frequency