6. Error Messages
Express5800/R310e-E4, R320e-E4, R320e-M4, R310f-E4, R320f-E4, R320f-M4 Maintenance Guide (Windows)
55
Chapter 1 Maintenance
(1)
System POWER LED
LED indication
Description
Action
On (green)
Either or both of CPU/IO modules are powered on.
–
Off
Both of CPU/IO modules are powered off.
–
(2)
System FAULT LED
LED indication
Description
Action
Off
Both of CPU/IO modules are offline or normal.
System FAULT LED does NOT notify of
disk statuses. Check it according to
(5)
DISK ACCESS LED
indication.
On (amber)
One of the CPU/IO modules failed.
Take a note of LED indications on
EXPRESSSCOPE, and then contact
your sales representative.
Blinking (amber)
One of the CPU/IO modules failed.
Failed CPU/IO module cannot be identified.
Contact your sales representative.
(3)
System FT LED
LED indication
Description
Action
On (green)
System is operating under duplex condition.
–
Off
System is not duplexed.
–
(4)
System ID LED
LED indication
Description
Action
On (blue)
UID switch is pressed.
–
Blinking (blue)
The server is receiving an identification request sent
by remote.
–
Off –
–
Module ID LED
Management LAN
connector
SPEED LED
LINK/ACT LED
1GLAN connector
10GLAN connector
(R320e-M4, R320f-M4 only)
Power Unit LED
< Rear >