Configuring Your Server 4-5
Memory
To enable the memory degradation feature
Select [Advanced] - [Memory/Processor Error] - [Halt].
To check the installed memory (DIMM board) status
Select [Advanced] - [Memory Configuration] and check the status indications.
The on-screen DIMM group numbers and socket locations on the IO board are associated
as shown in the following figure.
To clear the memory (DIMM board) error information
Select [Advanced] - [Memory Configuration] - [Memory Retest] - [Yes] and reboot.
Select [Server] - [Clear FRU LED] - [Yes] and reboot.*
* Only when [Server] - [FRU LED Feature] - [Enabled] has been selected.
To enable the memory mirroring feature or memory RAID feature
Select [Advanced] - [Memory Configuration] - [Memory RAS Feature], and select
[Mirror] or [RAID].
DIMM #1
DIMM #2
DIMM #3
DIMM #4