8-18 Troubleshooting
Problems with NEC EXPRESSBUILDER
When the server is not booted from the NEC EXPRESSBUILDER DVD, check the following:
T
Did you set the NEC EXPRESSBUILDER during POST and restart the server?
→
If you do not set the NEC EXPRESSBUILDER during POST and restart the
server, an error message will appear or the OS will boot.
T
Is BIOS configuration correct?
→
The boot device order may be specified with the BIOS SETUP utility of the server.
Use the BIOS Setup utility to change the boot device order to boot the system
from the optical disk drive first.
<Menu to check: [Boot]>
T
If [OS installation ***default***] is selected at BOOT Selection screen, following
message is displayed.
After this message appears, check the error and take the appropriate corrective action
according to the message listed in the table below.
Message
Cause
This EXPRESSBUILDER version was not
designed for this computer.
Insert the correct version and click [OK].
(When you click [OK], the computer reboots.)
This NEC EXPRESSBUILDER version is
not designed for this server.
Execute the NEC EXPRESSBUILDER on
the compliant server.
EXPRESSBUILDER could not get the
hardware parameters written in this
motherboard.
This version is not designed for this computer
or the motherboard may be broken. (When
you click [OK], the computer reboots.)
The hardware parameters written in this
motherboard are incorrect.
This version is not designed for this computer
or the motherboard may be broken.
This message is shown when NEC
EXPRESSBUILDER could not find
system-specific information because of
mother board exchange and so on.
Summary of Contents for Express5800/110Ge
Page 31: ...General Description 2 5 Rear View 1 2 3 2 4 5 6 7 8 9 10 12 11 13 ...
Page 48: ...2 22 General Description This page is intentionally left blank ...
Page 216: ...9 6 Upgrading Your Server 3 Loosen the two screws 4 Hold the side cover securely to remove it ...
Page 217: ...Upgrading Your Server 9 7 5 Position the server until on its right side ...
Page 256: ...9 46 Upgrading Your Server This page is intentionally left blank ...
Page 266: ...10 10 Internal Cabling Diagrams This page is intentionally left blank ...
Page 268: ...A 2 Specifications This page is intentionally left blank ...
Page 276: ...C 2 IRQ This page is intentionally left blank ...
Page 328: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Page 332: ...G 4 Product Configuration Record Table This page is intentionally left blank ...