5-12 Procedures after Completion of Installation
Manually install CPU module
1.
Confirm which CPU/IO module is the primary.
CPU/IO module 0 is the primary
–
Path of CPU module to be installed is 1.
CPU/IO module 1 is the primary
–
Path of CPU module to be installed is 0.
2.
Install CPU module (Run the following command depending on the status of
CPU/IO module)
- CPU/IO module 0 is the primary
# /opt/ft/bin/ftsmaint bringup 1
Completed bringUp on the device at path 1.
- CPU/IO module 1 is the primary
# /opt/ft/bin/ftsmaint bringup 0
Completed bringUp on the device at path 0.
Confirm LEDs illuminate in green.
Status lamp 2 of CPU/IO module 0: Green
Status lamp 2 of CPU/IO module 1: Green
Enable auto reinstallation of CPU module
1.
Confirm auto reinstallation of CPU module is disabled.
# /opt/ft/bin/ftsmaint bringupPolicy list
CPU bringup policy is deferred.
2.
Enable auto reinstallation of CPU module
# /opt/ft/bin/ftsmaint bringupPolicy enable
Successfully deferred cpuBringupPolicy.
3.
Confirm auto reinstallation of CPU module is enabled.
# /opt/ft/bin/ftsmaint bringupPolicy list
CPU bringup policy is enabled.