28 NCB Service Manual
Version 1.0
WARNING
DO NOT adjust or attempt to measure gas valve outlet
pressure. The gas valve is factory-set for the correct
outlet pressure. This setting is suitable for natural gas
and propane, requiring no field adjustment.
Attempting to alter or measure the gas valve outlet
pressure could result in damage to the valve, causing
potential severe personal injury, death or substantial
property damage. Navien NCB boilers are shipped
ready to fire natural gas ONLY.
Figure 5. Exploded view of Gas assembly
DANGER
See Figure 5. Inspect the O-ring between the gas valve
and gas valve inlet adapter whenever they are
disassembled. The O-ring must be in good condition and
must be installed. Failure to comply will cause a gas leak,
resulting in severe personal injury or death.
Figure 6. Orifice identification
12.
Replace the old Orifice piece with the new part for use with
LP gas. Ensure that the Orifice is properly seated inside the
port before proceeding to the next step.
13.
Replace the gas inlet pipe to its original position and use all
screws to secure all connections.
NOTE
Do not overtighten as this may damage or crack the
components.
DANGER
Inspect the O-ring between the gas valve and gas valve
inlet adapter whenever they are disassembled. The O-ring
must be in good condition and must be installed. Failure
to comply will cause a gas leak, resulting in severe
personal injury or death.
Gas Orifice
O-ring
Summary of Contents for NCB-180
Page 3: ......
Page 16: ......
Page 135: ...132 NCB Service Manual Version 1 0 7 2 Burner Assembly...
Page 139: ...136 NCB Service Manual Version 1 0 7 4 Fan Gas Assembly...
Page 142: ...Memo...
Page 143: ...140 NCB Service Manual Version 1 0 Memo...
Page 144: ...Memo...
Page 145: ...142 NCB Service Manual Version 1 0 Memo...
Page 146: ...Memo...
Page 147: ...144 NCB Service Manual Version 1 0 Memo...
Page 148: ...Memo...