86
Error conditions and Symptoms Analysis
5.15. 15Error
Check method
Error
Description
If an error occurs in the internal circuit of the PCB (e.g., resistance, transistor or
relay fault), the system displays 15E PCB error message.
15E
PCB error
Check
items
1. Defective PCB
2. Check, with a tester, if the PCB is in the rated voltage (AC 97V~138V).
3. Disconnect the grounding wire, and check the PCB.
Fault
Possible
Causes
Check method
Replace the PCB if there is an error in the PCB internal circuit.
Check, with a tester, if the PCB is in the rated voltage.
Check, with a tester, if the voltage at the receptacle is
97V~138V.
Power supply grounding noise causes malfunction.
Disconnect ground by applying a tape on the grounding
terminal in the receptacle, and check if the PCB works normally.
15E
PCB error
Defective
PCB
Power supply
error
Power supply
grounding
noise
Replace the main
PCB
After press reset button to normal?
No
Yes
Normal state
©
Navien
Ameri
c
a
I
n
c
.
20
1
0
CH
series
servi
c
e
Manua
l
Version
1
.0
Summary of Contents for CH-180
Page 2: ......
Page 31: ...29 4 4 Wiring Diagram Navien America Inc 2010 CH series service Manual Version 1 0...
Page 143: ...Navien America Inc 2010 CH series service Manual 141 Version 1 0 9 2 Burner Disassemble G...
Page 146: ...Navien America Inc 2010 CH series service Manual 144 Version 1 0 9 3 Water Way Disassemble...
Page 152: ...Navien America Inc 2010 CH series service Manual 150 Version 1 0 Memo...
Page 153: ...Navien America Inc 2010 CH series service Manual 151 Version 1 0 Memo...
Page 154: ...Navien America Inc 2010 CH series service Manual 152 Version 1 0 Memo...
Page 155: ......