84
Error conditions and Symptoms Analysis
5.13. 13Error
Error
Description
The system receives change of pressure from the water pressure sensor. If no
change of pressure is made for 7 seconds after starting of the pump, the system
stops/restarts the pump 3 times. If the pressure is remained unchanged, the system
determines a trouble of the pump, and displays the 13E (manually cancelled) error
message on the remote controller.
13E
Pump error
Check
items
Check if the pump works normally.
If the pressure remains unchanged after the pump is started, replace the pressure
sensor.
Pressure sensor error.
The pump can be stuck from time to time due to debris in the heating water.
Press the reset button,
is the pump normal?
Yes
No
During pump operating,
does water pressure increase
higher than 3.0 Psi.
Check connector(CN18)
or replace pump
Yes
No
Normal state
Repeat pump on and off
N times, if N < 5?
Remove air from pipe
No
Yes
©
Navien
Ameri
c
a
I
n
c
.
20
1
0
CH
series
servi
c
e
Manua
l
Version
1
.0
Summary of Contents for CH-180
Page 2: ......
Page 31: ...29 4 4 Wiring Diagram Navien America Inc 2010 CH series service Manual Version 1 0...
Page 143: ...Navien America Inc 2010 CH series service Manual 141 Version 1 0 9 2 Burner Disassemble G...
Page 146: ...Navien America Inc 2010 CH series service Manual 144 Version 1 0 9 3 Water Way Disassemble...
Page 152: ...Navien America Inc 2010 CH series service Manual 150 Version 1 0 Memo...
Page 153: ...Navien America Inc 2010 CH series service Manual 151 Version 1 0 Memo...
Page 154: ...Navien America Inc 2010 CH series service Manual 152 Version 1 0 Memo...
Page 155: ......