4.6.21. Auto Feeder Valve
Navien Part No.
Function
Check Point
BH0904011A
O
Failure Event
1. Water filling system does not operate automatically.
2. Water filling system operates continuously.
Effects
Error Code
E02
Diagnostic
Color /
Number of wires
Blue-Blue : ON AC 97 ~ 138 V, OFF 0 V
Detect low and high water pressure using the electronic water pressure
sensor If water pressure is low, Water filling system operates automatically
1. System is low water pressure
2. If system is high water pressure for automatic filling, it is over flow
1. Visual inspection: check the Auto feeder valve connection wire.
2. Voltage check: Check range of voltage shown below.
©