8. Replacement of Parts
8.1. Replacement Procedure
DANGER
1. When performing maintenance and/of servicing the combination boiler,
always turn off the electric power, gas and water shut-off valve. Wait for the
boiler to become cool. Be careful to avoid injury to your fingers on sharp edges.
2. Drain all water from the boiler when removing the water parts.
3. Before any disassembly, make sure you have a good diagnosis.
4. Handle all parts carefully.
5. When reassembling, prevent any foreign substance, i.e. dust, etc. from being
introduced into the boiler.
6. After reassembling, check for gas and water leakage. Then, test ignition.
Make sure that there is no gas leakage in connections by testing with soap
bubble solution. Bubbles indicate a gas leak that must be corrected.
7. Check the performance and operation after servicing.
NOTICE
When disassembling and reassembling the combination boiler, refer to the
components diagram & parts list.
To remove and replace any parts on this unit, you will need a magnetic tip screwdriver
that is at least 8 ~ 10 inches long. A flashlight and magnetic tip reach are also handy.
Navien recommends the use of a parts tray or bowl to hold small parts and screws. All
of the hardware is essential to the proper operation of the unit upon re-assembly.
118
Summary of Contents for CH-180
Page 2: ......
Page 31: ...29 4 4 Wiring Diagram Navien America Inc 2010 CH series service Manual Version 1 0...
Page 143: ...Navien America Inc 2010 CH series service Manual 141 Version 1 0 9 2 Burner Disassemble G...
Page 146: ...Navien America Inc 2010 CH series service Manual 144 Version 1 0 9 3 Water Way Disassemble...
Page 152: ...Navien America Inc 2010 CH series service Manual 150 Version 1 0 Memo...
Page 153: ...Navien America Inc 2010 CH series service Manual 151 Version 1 0 Memo...
Page 154: ...Navien America Inc 2010 CH series service Manual 152 Version 1 0 Memo...
Page 155: ......