35
4.6.3. Transformer
Navien Part No.
Function
Check Point
BH1205008A
H, K, S
Failure Event
1. There is no power coming from the transformer.
2. The voltage from the power supply cannot be converted to 120 VAC.
Effects
Error Code
N/A
Diagnostic
Color /
Number of wires
1. [AC 9 V] Yellow – Yellow : AC 7 ~ 11 V
2. [AC 26 V] White – White : AC 22~33 V
3. [AC 19 V] Blue – Blue : AC 16~24 V
4. [Power trans AC 150 V] Red – Red : AC 123~177 V
5. [Power trans AC 120 V] White – Black : AC 97~138 V
1. To supply power to the main PCB board.
2. Every electrical component of the unit is designed to only work with a
120VAC power supply; therefore, the unit comes equipped with this
transformer.
1. The unit does not operate due to lack of power from transformer.
2. A failed transformer can cause electrical damage to other electrical
components within the unit.
1. Visual inspection: Connection and/or breakage of wires and/or signs of
electrical damage.
2. Voltage check: Check range of voltage shown below.
ڜڞڍڑڱ
ڌ ڍ
ڎ ڏ
ڜڞڌڐڋڱ
ڜڞڔڱ
ڜڞڌڍڋڱ
ڌ ڍ
ڎ ڏ
ڌ
ڍ
ڎ
ڏ
ڌ ڍ
ڎ ڏ
©
Navien
Ameri
c
a
I
n
c
.
20
1
0
CH
series
servi
c
e
Manua
l
Version
1
.0
Summary of Contents for CH-180
Page 2: ......
Page 31: ...29 4 4 Wiring Diagram Navien America Inc 2010 CH series service Manual Version 1 0...
Page 143: ...Navien America Inc 2010 CH series service Manual 141 Version 1 0 9 2 Burner Disassemble G...
Page 146: ...Navien America Inc 2010 CH series service Manual 144 Version 1 0 9 3 Water Way Disassemble...
Page 152: ...Navien America Inc 2010 CH series service Manual 150 Version 1 0 Memo...
Page 153: ...Navien America Inc 2010 CH series service Manual 151 Version 1 0 Memo...
Page 154: ...Navien America Inc 2010 CH series service Manual 152 Version 1 0 Memo...
Page 155: ......