99
Check method
Error type
Cause
Check method
Remark
Check connector assembly and contact of the air
pressure sensor.
1. Black + White
Operating voltage: 5V
2. Black + Red
Sensor output
Open: 0.1±0.1V or lower
Short-circuit: 4.5±0.2V or higher
An error occurs if the air pressure sensor voltage of
1.20V is detected before prepurge.
If the trouble continues despite the checking of above
items, replace the PCB.
<Check the voltage of the air pressure sensor>
Abnormal
sensor
Other
trouble
Disconnector
Abnormal
air pressure
sensor
Defective
PCB
©