Service Manual Chapter7. Cash Dispenser Unit
© 2013
Nautilus Hyosung Inc.
All Rights Reserved.
7-30
Cash Low Sensor
► CS16, CS26, CS36, CS46
1. Loosen the Sensor Bracket M3 fixing screw (2 places).
2. Press the snap lock from the rear side of the Sensor Bracket with hands to remove.
Then, remove the sensor.
3. Disconnect the connector. Be careful not to break the connector pin when removing
4. Replace the sensor.
5. Connect the connector.
6. To assemble the sensor in the bracket, lock it from the front side and press the rear
side to fix it.
<Note!>
Adjust the sensor by running the variable resistance so that it generate below
1.0V if remaining amount is available. Otherwise, set it above 3.0V.