Service Manual Chapter7. Cash Dispenser Unit
© 2013
Nautilus Hyosung Inc.
All Rights Reserved.
7-54
Setting Specifications
Dip Switch Setting
► Dip Switch Settings
► Dip Switch on Controller Board
DIP SWITCH
DESCRIPTION
1
2
3
4
5
6
7
8
On
On
On
On
On
On
On
On
Transaction Mode
Off
On
On
On
On
On
On
On
Program Download Mode
On
Off
→ On
On
On
On
On
On
On
Automatic Sensor Default
mode
On
On
Off
→ On
On
On
On
On
On
Automatic Sensor
Adjustment mode
► How to download Cash Dispenser Program
1. Turn power off
2. Completely put ROM Pack board for downloading into CDU main board
3. Turn on the No 1 DIP switch and then turn power on power supply
4. Check 7 segments changing as follows
: ‘L0’→ ‘L6’→ ‘L7’→’0’ or Off
5. Turn power off and carefully remove ROM Pack board.
6. Turn off No 1 Dip switch
7. Turn on power and initialize CDU
► In case No2 or No3 switch will be used
1. When the sensor (CS4, CS10, CS
13, CS14) is clean : The ‘Initialize’ button on Cash
Dispenser diagnostic mode should be pressed
2. When the control board is replaced :
Execute Dip switch 2 Off/On and Dip switch 3 Off/On
3. When sensor error occurred :
- Check if there remain dusts or unknown objects on sensor, and the remove them
completely.
-
Press the ‘Initialize’ button on Cash Dispenser diagnostic mode
- If error is not clear in case above actions are taken
: Run the Automatic Sensor Adjustment mode (Dip switch 3 Off/On)