background image

Installation Manual

HydraIP

APC-R module

Manual Version: 1.2.0
Date: 23.11.2017

Read the manual carefully befor use!
Keep the manual!

Summary of Contents for HydraIP APC-R

Page 1: ...Installation Manual HydraIP APC R module Manual Version 1 2 0 Date 23 11 2017 Read the manual carefully befor use Keep the manual ...

Page 2: ...e counting modules 2 1 5 Application of templates and installation of counting modules 2 2 5 Back door 2 2 1 11 Front door 2 2 2 12 Measuring the counting module 2 3 3 Interfaces 13 4 Power supply of counting module 14 14 Connection to the power supply of the recorder over a relay 4 1 5 Setting IP addresses of the counting modules 16 0 ...

Page 3: ...llation This manual describes the installation of APC R people counter modules using the Derovis counter module fixture using a Citaro standard bus Only Derovis APC R counting modules can be used for the Derovis Automatic People Counting system APC External devices can not be used ...

Page 4: ...r cordless screw gun Countersink or 10mm drill bit Hexagon socket screw bit 7 mm 2 1 Preparing the counting modules The counting modules are to be taken out of the package and screwed to the fixture It important to ensure the lenses are not polluted or scratched during the process The packaging material is very useful as an underlay The counting module should be mounted to the fixture Both attachm...

Page 5: ...hind the cover for the counting module the template has to be possibly adjusted a bit 2 2 1 Back door The template should be centered above the door about 20 cm from the top edge While determining the center you should orient yourself to the door and not the cover Sometimes there are fixtures above the door that might be helpful e g red in picture Mark the cutout inner area of template and drill h...

Page 6: ...Installation of counting module HydraIP APC R module Version 1 2 0 Datum 23 11 2017 Seite 6 Check again using a measuring tape or similar if the cutout is sitting straight Carefully cut out Drill holes ...

Page 7: ... module HydraIP APC R module Version 1 2 0 Datum 23 11 2017 Seite 7 Trim edges and drill holes Since the material is very weak you should work very carefully Clean thoroughly afterwards Now you can place in the module fixture ...

Page 8: ...nsparent protective cover from the backside It is absolutely necessary to clean the backside of the cover in the installation area of any dust Next the protective housing is set in place the flattened side facing upward and the six bolts of the long side with adquate washers and appropiate screws are prepared ...

Page 9: ... 2 0 Datum 23 11 2017 Seite 9 The screws should be inserted diagonally and turned lightly 7mm hexagon socket screw bit At the same time you should make sure that the aluminum frame fits evenly against the cover on the other side It is necessary to switch hands now ...

Page 10: ... the counting module with clean hands in order to keep the white module clean Next roughly adjust the counting module e g in the Citaro between the second and third adjusting screw hole counting from the bottom The counting module should point in the direction of the bottom edge of the door when closing the cover ...

Page 11: ... Front door Same installation process as the back door but The cutout should have a 2 cm gap from the top edge of the cover i e the top edge of the template should have a gab of 1 cm to the edge of the cover It is absolutely necessary to check if there are any interfering components behind the cover ...

Page 12: ...Datum 23 11 2017 Seite 12 2 3 Measuring the counting module The installation height and angle of the camera has to be measured and written down for every door while the covers are shut tight The information is needed later for the software configuration of the cameras ...

Page 13: ...utput 8 DID_IN 1 Coding Pin 1 Input 9 DID_OUT 0 Coding Pin 0 Output 10 DID_IN 0 Coding Pin 0 Input 11 DOOR Negative terminal of door contact Input 12 DOOR Positive terminal of door contact Input 13 Power Supply Negative terminal GND Input 14 Power Supply Positive terminal U IN Input Do not connect the door contacts Pin no 11 12 of the Counting modules The door contacts need to be connected with th...

Page 14: ...cle voltage 24 VDC by using a relay 24VDC with integrated flyback diode controlled by the digital output of the recording system Also consult the manual of the recording system for more information A short cable for the control circuit of the relay should be made Male contacts are to be used for the connectors Plus red wire is to be inserted into PIN 1 on an bi polar AMP connector This connector s...

Page 15: ...Power supply of counting module HydraIP APC R module Version 1 2 0 Datum 23 11 2017 Seite 15 The control circuit should be assembled with the the AMP connector ...

Page 16: ...e counter will automatically have the default IP address 192 168 100 10 The IP addresses need to be set manually for every counting module You can select an IP address by connecting a pair of Coding pins of the 14pin Connector plug e g Connect pin 9 10 Coding PIN 0 to select IP address 192 168 10 1 Backside of the 14pin male connector Connect pin 7 8 Coding PIN 1 to select IP address 192 168 10 2 ...

Page 17: ...Tel Derovis GmbH 49 0 30 515 932 100 E Mail contact derovis de www derovis de ...

Reviews: