DIN(48X48mm) Digital c ounter
Range 1 - 999999with UP/DOWN mode, Max.10kpcs
Preset scale range :0.001-99.999

preset scale count function

MCU for digital control, High accuracy and reliability
EEPROM store data for 10 years
NPN and PNP input switchable
9.2mm height LED, prevent dazzle, highly visible display
Tact switch for up or down set value, easily operate
Key lock function, prevent mistake operation
Switching power supply a nd low c onsumption

Preset scale range:

Power and input:
Voltage(Ordering):

Cha racter :

Contact output

:

SSR output

:

Life expecta ncy:

Max.counting speed:

Data backup:
Control signals:
Control/Input type:
Input level:

External power:
Star t timing:
Reset method:
Cutout size:
Mounting Method:
Weight:
Ambient temperatur e:

(C3E -R)

(C 3E-V)

10kpcs(Rate 1:1),100Hz,5KHz,10KHz
0.001-99.999

The power supply and input circuit are isolated.
AC 100-240V

10% 50/60Hz

5VA

AC/DC 12-24V

10%

4VA

PV: 6 digital 9.2mm height, high light red LED
SV: 6 digital 7.0mm height, high light green LED
AC 250V 3A(Resistive load) NO/NC
DC12V( Max.40mA)
Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min.

10 years,Data ca n be stor e or not by setting

5ms (Reset, Gate)

Contact/No-voltage input(NPN)/ Voltage input(PNP)
High(logic) 4.5 t o 30 VDC
Low(logic) 0 to 2.0 VDC
DC 12V/50mA(Max.) for sensor use only.

100ms

Power on/External/Manu al
45X45 mm
Flush mounting and screw terminals
Approx. 120g
Operating: -10

55

(with no icing or condensat ion)

Storage: -25

65

(with no icin g or condensation)

35

85% RH

±

±

SESTOS

TM

MD

RST

MD

RST

MD

MD

MD

MD

D.P.position

M D

MD

MD

SESTOS

TM

MD

RST

COUNTER

C3E

UP

1
2
3 4
5 6

MD

RST

1

2

3

4

1

2

3

4

5

6

Group 1

key

setting digital

Group 2

key

setting digital

Group 3

key

setting digital

Group 4

key

setting digital

10KHz

5KHz

100Hz

Max.counter speed

DP 0

DP 1

DP 2

DP 3

This product must be mounte d on the panel, a void electric shock.


When the power is turned on, is not connecting the terminal, avoid electric shock.

Ensure the produc t within the spec ification.
Never disassemble, repair or modify the pr oduct, if needed please c ontact agent or us

Do not use the pro duct in locations subject to gases , dust, vibration, corrosive direct sunlight,
water and oil, strong EMI

Ambient humidity:

: Output

U P

:M ode
:Reset
:Up
:Down
:Pr esent Value
:Set Value

Indicator:

: Light--Reset; Blink--P ause
: Key Lock

Power On

PV

SV

Press
key over 3s

Press
key over 3s

MD

MD


1.Change the run mode to setti ng mode the operation is continuous.
2.Retu rn to the run mode and automatic reset when change the

function setting .

3.When function mode ,four "

" and "

" key are same function.

If no change the setting r eturn to the run mode after 60 second, and
the setting is saved same time automatic reset.

Input Mode

UP

UP Mode

DOWN

Down Mode

Counter

speed

Output time

(second)

1.When output time set to

,display

and self-holding output until

reset signal.

2.When output time set to

--

s; Automatically reset after time is up.

Preset s cale

Range :0.001-99.999 (decimal point position is fixed)

Input s elect

NPN: No-volta ge input

PNP: Voltage input

Fig 1

ON : Save the PV and state when Power off

OFF: Not s ave the PV and s tate when power off

OFF: Unlock

ON: Lock RST

key

(See fig 1)

、 ︽︾

Save PV

and state

Key Lock

Reviews: