Narda
IDA
-
3106
209
To select a trace type/detector:
1.
Press the
View
softkey and select a view.
2.
Press
OK
or
ESC
to exit from the menu.
3.
Press the
Trace / Detector
softkey, select an item using the rotary
control knob, and press
OK
to set the selection.
11.3.6 Setting the Persistence Range
I⁄Q Analyzer • View: Persistence
Different colors are used in the
Persistence Spectrum
view to represent
how often different amplitude values occur at a given frequency. You can set
the number of decades displayed from 2 to 4 decades by selecting one of
the six different ranges using the
Persistence Range
softkey in the Display
menu. The example in Figure 50 has a range set from 0.1 % to 100 %
showing 3 decades. A suitable value is set automatically if you select
Auto
decade.
Persistence Spectrum
view is selected.
1.
Press the
Display
softkey.
2.
Press the
Persistence Range
softkey, select a range using the rotary
control knob, and press
OK
to set the selection.
11.4
Using the trigger function
I⁄Q Analyzer • Trigger Menu
The trigger function allows you to trigger a measurement when the
observed input signal meets the specified conditions. After the
measurement is triggered and the set time span has elapsed, the display is
"frozen" so you can see the signal characteristic. The Magnitude is always
used as the trigger source to which all other trigger parameters refer. A
video bandwidth can be selected to smooth signal peaks.
11.5
Saving measured values automatically
The Auto Save function allows you to save measured values automatically
when a trigger event occurs.
Summary of Contents for IDA
Page 1: ...IDA 3106 Interference and Direction Analyzer Operating Manual IDA IDA 2...
Page 8: ...Contents VI IDA 3106 Narda...
Page 28: ...2 Important Safety Instructions 20 IDA 3106 Narda...
Page 134: ...6 Common Functions 126 IDA 3106 Narda...
Page 166: ...7 Direction Finding Mode 158 IDA 3106 Narda...
Page 188: ...9 Level Meter Mode 180 IDA 3106 Narda...
Page 206: ...10 Time Domain Scope Mode 198 IDA 3106 Narda...
Page 218: ...11 I Q Analyzer Mode 210 IDA 3106 Narda...
Page 238: ...13 Measurement Data Memory 230 IDA 3106 Narda...
Page 242: ...14 Maintenance Repairs Updates 234 IDA 3106 Narda...
Page 246: ...15 PC Software 238 IDA 3106 Narda...
Page 254: ...16 Remote Control 246 IDA 3106 Narda...
Page 269: ...17 4 Antenna handle and antennas Narda IDA 3106 261 17 4 7 Antenna factors typical...
Page 272: ...17 Specifications 264 IDA 3106 Narda...
Page 284: ...19 Glossary 276 IDA 3106 Narda...
Page 290: ...Index 282 IDA 3106 Narda...
Page 291: ......