7.7 The Map menu
Narda
IDA
-
3106
151
Determining the transmitter location by distance
calculation (Distance)
Direction Finding • Map • Average Position
The
Distance
function is used to determine the location of a signal source
based on differences in signal level.
You can find more information about this method under
To use the Direction function:
Bearings are available in an open localization or a saved localization has
been recalled.
1.
Press the
Map
softkey then press the
Average Position
softkey.
The location cross and circle are displayed.
2.
Press the
Distance
softkey until
On
appears.
The distance function is activated. Black lines across the bearing
lines indicate the distance determined from the position from which
the particular bearing was taken.
7.7.9
Excluding bearings from the calculation
(Disable Bearing)
Direction Finding • Map • Marker
You can use the marker function to select individual bearings in a
localization and exclude them from the calculation of the location.
To use the marker function:
1.
Open the desired localization.
Average Position
must not be selected.
2.
Press the
Marker
softkey.
The first bearing is selected and marked in red.
3.
Select a bearing using the arrow keys
.
4.
To exclude a bearing from the calculation of the location, press the
Disable Bearing
softkey.
An excluded bearing is shown in gray.
5.
To reactivate all excluded bearings, press the
Enable all Bearings
softkey.
6.
To delete a bearing, press the
Delete Bearing
softkey.
The selected bearing is deleted from the localization.
Summary of Contents for IDA
Page 1: ...IDA 3106 Interference and Direction Analyzer Operating Manual IDA IDA 2...
Page 8: ...Contents VI IDA 3106 Narda...
Page 28: ...2 Important Safety Instructions 20 IDA 3106 Narda...
Page 134: ...6 Common Functions 126 IDA 3106 Narda...
Page 166: ...7 Direction Finding Mode 158 IDA 3106 Narda...
Page 188: ...9 Level Meter Mode 180 IDA 3106 Narda...
Page 206: ...10 Time Domain Scope Mode 198 IDA 3106 Narda...
Page 218: ...11 I Q Analyzer Mode 210 IDA 3106 Narda...
Page 238: ...13 Measurement Data Memory 230 IDA 3106 Narda...
Page 242: ...14 Maintenance Repairs Updates 234 IDA 3106 Narda...
Page 246: ...15 PC Software 238 IDA 3106 Narda...
Page 254: ...16 Remote Control 246 IDA 3106 Narda...
Page 269: ...17 4 Antenna handle and antennas Narda IDA 3106 261 17 4 7 Antenna factors typical...
Page 272: ...17 Specifications 264 IDA 3106 Narda...
Page 284: ...19 Glossary 276 IDA 3106 Narda...
Page 290: ...Index 282 IDA 3106 Narda...
Page 291: ......