7.5 Localizing a signal source (Outdoor)
Narda
IDA
-
3106
139
7.5
Localizing a signal source (Outdoor)
This section describes the typical procedure for localizing a signal source
outdoors. You can find detailed information about individual functions such
as Average Position and Distance under
on page 143. You
can find a description of how to localize a signal source indoors under
Finding the location of a signal scource (Indoor)
You can determine the location of a signal source in two ways:
By triangulation
If you take bearings on a signal source
from several different locations, the
bearing lines will intersect within a small
area. The signal source is in this area. It
does not matter whether you have
determined the bearings from
Manual Bearing or Horizontal Scan. You
can determine the location on the basis of
the bearings using the
Average Position
function in the Map menu.
NOTE:
Triangulation is invalid if the bearings do not intercept or the angle between
the bearings is too acute. Choosing a different location may help you to get
a valid result.
From the distance
It can be time-consuming and require
travel over long distances to take
bearings on a signal source from different
locations. As an alternative, the power
level of the signal source can be
measured in the direction of the source
from two points far enough apart so that
the location can be determined from the
direction and the difference in signal
levels. The
Distance
function in the Map
menu is provided for this purpose. This method does require that the source
signal level is constant and that reflections are small (this is critical in street
canyons, for example).
A
B
C
A
B
Summary of Contents for IDA
Page 1: ...IDA 3106 Interference and Direction Analyzer Operating Manual IDA IDA 2...
Page 8: ...Contents VI IDA 3106 Narda...
Page 28: ...2 Important Safety Instructions 20 IDA 3106 Narda...
Page 134: ...6 Common Functions 126 IDA 3106 Narda...
Page 166: ...7 Direction Finding Mode 158 IDA 3106 Narda...
Page 188: ...9 Level Meter Mode 180 IDA 3106 Narda...
Page 206: ...10 Time Domain Scope Mode 198 IDA 3106 Narda...
Page 218: ...11 I Q Analyzer Mode 210 IDA 3106 Narda...
Page 238: ...13 Measurement Data Memory 230 IDA 3106 Narda...
Page 242: ...14 Maintenance Repairs Updates 234 IDA 3106 Narda...
Page 246: ...15 PC Software 238 IDA 3106 Narda...
Page 254: ...16 Remote Control 246 IDA 3106 Narda...
Page 269: ...17 4 Antenna handle and antennas Narda IDA 3106 261 17 4 7 Antenna factors typical...
Page 272: ...17 Specifications 264 IDA 3106 Narda...
Page 284: ...19 Glossary 276 IDA 3106 Narda...
Page 290: ...Index 282 IDA 3106 Narda...
Page 291: ......