17 Specifications
256
IDA
-
3106
Narda
17.3.5 Time Domain (Scope)
Filter
• Type: Steep cut-off channel filter (app. raised cosine)
• Roll-off factor: 0.16
Video bandwidth (VBW)
0.01 Hz to 32 MHz or off,
Coupled with selected CBW (VBW = CBW/1 … CBW/10000)
Max Hold
Available for Peak and RMS detectors
Noise threshold
Selectable at 0, 3, 6, 10, 15, or 20 dB relative to device noise floor.
Measurement values below the threshold are shown as
“
<
absolute threshold value”.
Measurement principle
Selective level measurement at a selectable frequency
from 9 kHz to 6 GHz
Channel bandwidth CBW,
(-6 dB nominal)
100 Hz to 32 MHz
In steps of
100, 125, 160, 200, 250, 320, 400, 500, 640, 800, 1000 Hz,…
10 MHz, 13.33 MHz, 16 MHz, 20 MHz, 26.67 MHz, 32 MHz
Filter
• Type: Steep cut-off channel filter (app. raised cosine)
• Roll-off factor: 0.16
Video bandwidth (VBW)
0.01 Hz to 32 MHz or off
Coupled with selected CBW (VBW = CBW/1 … CBW/10000)
Measurement
High Resolution Scope
• Measures the actual magnitude, max. 250000 samples
• Time resolution coupled to 1/CBW (31.25 ns to 10 ms)
Long-Time Scope
• Uses selectable detectors to measure the magnitude
• Time Span 4 µs to 24 h (resolution 250 ns)
Detector
+Peak, RMS, -Peak
can be selected individually for Long-Time Scope
Evaluation functions
Duty cycle (ratio of average power to maximum power) including
Time Domain Power
Triggering
• Free run, single, multiple, time controlled
• Programmable trigger level, trigger slope and trigger delay
Magnifier (Graphical Zoom)
• Simultaneous display of the selected trace and an enlarged view
of the section of interest
• Magnification level of 25 x and 500 x for High Resolution Scope
and 10 x and 50 x for Long-Time Scope
Summary of Contents for IDA
Page 1: ...IDA 3106 Interference and Direction Analyzer Operating Manual IDA IDA 2...
Page 8: ...Contents VI IDA 3106 Narda...
Page 28: ...2 Important Safety Instructions 20 IDA 3106 Narda...
Page 134: ...6 Common Functions 126 IDA 3106 Narda...
Page 166: ...7 Direction Finding Mode 158 IDA 3106 Narda...
Page 188: ...9 Level Meter Mode 180 IDA 3106 Narda...
Page 206: ...10 Time Domain Scope Mode 198 IDA 3106 Narda...
Page 218: ...11 I Q Analyzer Mode 210 IDA 3106 Narda...
Page 238: ...13 Measurement Data Memory 230 IDA 3106 Narda...
Page 242: ...14 Maintenance Repairs Updates 234 IDA 3106 Narda...
Page 246: ...15 PC Software 238 IDA 3106 Narda...
Page 254: ...16 Remote Control 246 IDA 3106 Narda...
Page 269: ...17 4 Antenna handle and antennas Narda IDA 3106 261 17 4 7 Antenna factors typical...
Page 272: ...17 Specifications 264 IDA 3106 Narda...
Page 284: ...19 Glossary 276 IDA 3106 Narda...
Page 290: ...Index 282 IDA 3106 Narda...
Page 291: ......