![Napoleon Condo Pack Installation And Operating Instructions Manual Download Page 7](http://html1.mh-extra.com/html/napoleon/condo-pack/condo-pack_installation-and-operating-instructions-manual_3307042007.webp)
7
IOM
W415-2288 / 08.29.2019
4. INSTALLATION
The unit is shipped in one
package, completely assembled
and wired.
The air conditioning condensate
drain is shipped separately with
the unit for field install.
If any damage is found, proper
notation should be made on the
carrier’s freight bill. Damage
claims should be filed with the
carrier as quickly as possible.
Check the rating plate (at the
front of the access panel) to
confirm heating and cooling
capacities.
The unit should be operated only
with the electrical supply noted on
the rating plate.
SUPPLY OUTLET
RETURN
INLET
HEATING
MODULE
FILTER
ELECTRICAL
SLOT
CABINET
ACCESS
PANEL
WALL
SLEEVE
AC
DRAIN
COOLING
SECTION
H8.2.3
1. The unit must not be located in an area where the return air may contain chemical compounds such as
bromine, chlorine or fl uorine, as may be found in swimming pool chemicals, laundry detergents, etc. These
compounds when exposed to fl ame, form acids which attack the heat exchanger and other components.
Exposure to the following substances in the return air supply (but not limited to the following) are not
allowed, and will affect warranty claims:
• Aerosols, particularly CFC based or propelled aerosols
• Air fresheners
• “Airplane Glue” and similar adhesives and cements
• Ammonia, as commonly found in permanent wave solutions used in hair dressing salons
• Anti-static fabric softeners used in clothes dryers
• Carbon tetrachloride
• Chlorinated cleaners and waxes
• Chlorine and bromine based swimming pool chemicals
• De-icing salts or chemicals (rock salt, etc.)
•
Dry cleaning fl uids such as perchloroethylene
• Fumes from curing polyurethane and similar substances
• Halogen based refrigerants including R-12 and R-22
• Hydrochloric acid, muriatic acid and other acid based masonry washing and curing materials
• Printer’s inks, paint removers, varnishes, varsol, toluene, etc.
• Water softener salt and chemicals
2. If the unit is installed in an area where freezing may occur, a garage, an attic, a crawl space or any
unconditioned space, steps must be taken to protect the condensate trap and drain line from freezing.
FIG. 4.0
H3.91
DO NOT INSTALL CONDOPACK UNIT IN UNCONDITIONED SPACE. THE AMBIENT OF THE
MECHANICAL ROOM IN WHICH CONDOPACK UNIT IS TO BE INSTALLED MUST BE KEPT
AT LEAST 55°F DURING HEATING SEASON. THERE MUST NOT BE ANY AIR
INFILTRATION FROM OUTDOORS INTO THE MECHANICAL ROOM. ANY OPENINGS IN
EXPOSED EXTERIOR WALL FOR DUCTING AND PIPING MUST BE COMPLETELY SEALED.
WARNING
!
!
BEFORE INSTALLATION, REMOVE THE UNIT SHIPPING BRACKETS AND
REPLACE THE SCREWS BACK INTO THE UNIT.
IMPORTANT
!
!
Summary of Contents for Condo Pack
Page 58: ...58 IOM IOM W415 2288 08 29 2019 9 3 P E HEATING MODULE...
Page 62: ...62 IOM IOM W415 2288 08 29 2019 44 1...
Page 63: ...63 IOM W415 2288 08 29 2019 44 1...
Page 122: ...58 IOM IOM W415 2288 08 29 19 9 3 MODULE DE CHAUFFAGE LECTRIQUE CONDO PACK P E...
Page 126: ...62 IOM IOM W415 2288 08 29 19 44 1...
Page 127: ...IOM W415 2288 08 29 19 44 1...