W415-2288 / 08.29.2019
H27.1_AC
DO NOT OPERATE THIS EQUIPMENT WITHOUT AN AIR FILTER.
CAUTION
A portion of the dust entrained in the air may temporarily lodge in the air duct runs and the supply registers.
Any recirculated dust particles will be heated and charred by coming into contact with the heat exchanger.
This residue will soil ceilings, walls, drapes, carpets, furniture, and other household articles.
BE SURE THAT THE FILTER IS RE-INSTALLED WITH THE AIRFLOW DIRECTION IDENTICAL
TO ITS PREVIOUS USE. REVERSING THE FILTER WILL CAUSE DUST TRAPPED WITHIN
THE FILTER TO BREAK FREE AND RECIRCULATE WITHIN THE DUCT SYSTEM. CONSULT
YOUR INSTALLATION CONTRACTOR OR SERVICE TECHNICIAN IF YOU HAVE ANY
QUESTIONS ON INSTRUCTIONS FOR REMOVING/REINSTALLING THE AIR FILTER.
CAUTION
!
!
H3.25.1.1
DISCONNECT THE ELECTRICAL POWER SUPPLY TO THE UNIT BEFORE ATTEMPTING ANY
MAINTENANCE. FAILURE TO DO SO CAN CAUSE ELECTRICAL SHOCK RESULTING IN
PERSONAL INJURY OR LOSS OF LIFE.
WARNING
!
!
!
!
All indoor return air must be filtered. A permanent-type filter is pre-installed with the unit. It is located on the air
conditioning section. The provided air filter is natural fiber washable filter and should be inspected frequently
and cleaned or replaced as necessary.
Follow these procedures before inspecting heating module.
• Turn room thermostat to its lowest or off setting.
•
Wait at least five minutes for heating module to cool if it was recently operating.
• Turn off unit electrical power; failure to do so could result in injury or death.
USE ONLY RECOMMENDED REPLACEMENT PARTS. FAILURE TO DO SO COULD CAUSE
IMPROPER HEATING MODULE OPERATION AND VOID THE WARRANTY.
IMPORTANT
!
!
Perform periodic preventive maintenance once before heating season begins and once before
cooling season. Inspect, clean and repair, as needed the following items:
• Check all electrical wiring and connections, including electrical ground.
• All supply air and return air ducts for obstructions, air leaks and loose insulation
• Inspect electric heating element limit switches for signs of excessive heat (scorched surfaces, cracking
of phenolic insulator)
• Blower housing/wheel and blower motor. Blower motors are equipped with permanently lubricated
bearings, and do not require oiling.
Power to the unit should always be turned OFF before performing service or removing the heating module
from the unit. One power harness and one control circuit harness are provided for easy disconnecting and re-
connecting of the wires between the cooling section and cabinet. The top front panel door must be removed to
allow access to the wiring harnesses.
7.2 HEATING MODULE
7.3 COOLING SECTION
7.4 AIR FILTER
The indoor blower motor and the outdoor fan motor have permanently lubricated bearings and do not require
routine service. The refrigeration system is sealed and factory charged with Refrigerant R-410A so that routine
maintenance is not required. Cleaning of the outdoor coil, indoor coil, drain pan, and inside the bottom of the
cooling section are recommended at least once a year, and more often if the equipment is operated in a dusty
or hostile environment. The electrical controls do not require routine service.
Summary of Contents for Condo Pack
Page 58: ...58 IOM IOM W415 2288 08 29 2019 9 3 P E HEATING MODULE...
Page 62: ...62 IOM IOM W415 2288 08 29 2019 44 1...
Page 63: ...63 IOM W415 2288 08 29 2019 44 1...
Page 122: ...58 IOM IOM W415 2288 08 29 19 9 3 MODULE DE CHAUFFAGE LECTRIQUE CONDO PACK P E...
Page 126: ...62 IOM IOM W415 2288 08 29 19 44 1...
Page 127: ...IOM W415 2288 08 29 19 44 1...