![Napoleon Condo Pack Installation And Operating Instructions Manual Download Page 3](http://html1.mh-extra.com/html/napoleon/condo-pack/condo-pack_installation-and-operating-instructions-manual_3307042003.webp)
3
IOM
W415-2288 / 08.29.2019
1. MODEL NOMENCLATURE
2. OVERVIEW
These instructions cover the installation of the Condo Pack, which consists of three separate sections: the wall
sleeve, the cabinet with the air conditioning (AC) section and the furnace module. Instead of replacing the
complete system, the furnace module can be partially or fully removed for servicing.
All control harnesses are separated with modular quick disconnects, so module replacement does not require
rewiring. All sections have been factory run-tested. and ready for easy installation.
These instructions are intended as an aid to the licensed service technician. Improper installation may damage
equipment, void the warranty, and can create a hazard, resulting in injury or death. Our HVAC systems and
components are designed to be installed by qualified HVAC technicians ONLY. The installation of HVAC
systems includes electrical and refrigerant connections and is regulated by a multiple set of laws, codes
and guidelines, at the federal, state and local levels. It is the installer’s responsibility to install the product in
accordance with all applicable codes and regulations. NO WARRANTY is offered for the products that were
installed by unlicensed/unauthorized persons. Failure to comply with this policy could lead to violations of
applicable laws that are punishable. Documentation and specifications are continuously updated and subject to
change. Please download the latest version of specifications and manuals at:
http://www.condopack.com.
P = Condo Pack
A, B, C...
Gas Condensing(96%)
030 - 30 000 BTU/h
015 - 15 000 BTU/h
040 - 40 000 BTU/h
050 - 50 000 BTU/h
NH - No heat
018 - 18 000 BTU/h / 1.5 ton
024 - 24 000 BTU/h / 2.0 ton
012 - 12 000 BTU/h / 1.0 ton
NC - No Cool
P
C
A
A
A
30
18
HEATING
CAPACITY
HEATING
TYPE
COOLING
CAPACITY
BRAND
COOLING
TYPE
COOLING
REVISION
A, B, C...
CABINET
REVISION
A, B, C...
A
HEATING
REVISION
C - Gas Condensing
S - Gas Standard
E - Electrical
D - Duct only (No heat)
i.e. P-DNHA-A18A-A
Electric Heat
NH - No heat
005 - 5.0 kW
007 - 7.5 kW
010 - 10 kW
015 - 15 kW
Gas Standard(80%)
038 - 38 000 BTU/h
026 - 26 000 BTU/h
051 - 51 000 BTU/h
064 - 64 000 BTU/h
NH - No heat
Heat designa�on
Heat designa�on
Heat designa�on
A - Single Stage
B - Blower Only (No Cool)
i.e. P-C15A-BNCA-A
EXAMPLE:
P-C15A-A18A-A
Condo Pack
Condensing Gas - High Efficiency Heat
15 000 BTU/h (Hea�ng Capacity)
Rev. A (Hea�ng Revision A)
Air Condi�oning - Single Stage
18 000 BTU/h (Cooling Capacity for 1.5 ton)
Rev. A (Cooling Revision A)
Rev. A (Cabinet Revision A)
Summary of Contents for Condo Pack
Page 58: ...58 IOM IOM W415 2288 08 29 2019 9 3 P E HEATING MODULE...
Page 62: ...62 IOM IOM W415 2288 08 29 2019 44 1...
Page 63: ...63 IOM W415 2288 08 29 2019 44 1...
Page 122: ...58 IOM IOM W415 2288 08 29 19 9 3 MODULE DE CHAUFFAGE LECTRIQUE CONDO PACK P E...
Page 126: ...62 IOM IOM W415 2288 08 29 19 44 1...
Page 127: ...IOM W415 2288 08 29 19 44 1...