5.2.2 Condenser Fan Removal
Thread the wiring out from both holes
completely out of the fan module.
To remove condenser fan, heating
module must be removed first.
Refer to steps 1-16 shown in “Heating
Module Removal”.
Remove two screws holding
side manifold cover baffle.
Remove side manifold cover baffle.
Un-install four screws that holding
heating module upper bracket .
Remove the bracket.
Pull out condenser fan assembly.
Remove condenser fan part.
Remove condenser fan shroud
mounting screws
(3 on the top and 7 at the bottom).
Remove rear manifold cover baffle.
Remove 4 rear manifold screws (one from the top).