5. ELECTRICAL
5.1 ELECTRICAL WIRING AND CONNECTIONS
5.1.1 Main Disconnect Switch
5.1.2 Service Disconnect Switch
• In Canada, all electrical work and grounding must be in accordance with the latest edition of CSA-C22.1,
Canadian Electrical Code Part 1, and any applicable local code. In the United States, all electrical work
must be in accordance with the latest edition of the National Electrical Code, ANSI / NFPA 70.
• The operating voltage of the unit is from 197 to 253 volts. Operating the equipment outside of these limits
will void the warranty.
• The wiring diagram Is located behind the heat module front access panel.
• Ensure that electrical components in the indoor section are protected from water.
The rating plate indicates the operating voltage, phase, ampacity, maximum fuse size, and minimum voltage
Refer to the rating plate located on the unit for proper fuse or breaker size.
It is mandatory to supply a unit with a SERVICE disconnect switch located
BEFORE
the unit, making sure that
one does not have to leave the unit perimeter in order to disconnect power to the unit.
Although it is not necessary, but is recommended that rooms with more than one entrance are equipped with a
separate unit SERVICE disconnect switch, located close the room entrance.
SHUT OFF ELECTRICAL POWER AT THE FUSE BOX OR SERVICE PANEL BEFORE
MAKING ANY ELECTRICAL CONNECTIONS. FAILURE TO DO SO CAN CAUSE
ELECTRICAL SHOCK RESULTING IN PERSONAL INJURY OR LOSS OF LIFE.
• THE CONDO PACK UNIT CABINET MUST HAVE AN UNINTERRUPTED GROUND.
FAILING TO GROUND THE UNIT PROPERLY CAN RESULT IN ELECTRIC SHOCK
RESULTING IN PERSONAL INJURY OR DEATH.
• A GROUND LUG IS LOCATED ON THE SIDE OF HEATING MODULE. Refer to:
“5.2 Removal of Heating Module, Condenser fan and Indoor Blower”
.
•
WARNING
!
!
THE SERVICE SWITCH SHOULD BE CLEARLY LABELED AND INSTALLED IN A LOCATION
WHERE IT IS NOT LIKELY TO BE MISTAKEN AS BEING A LIGHT SWITCH OR SIMILAR CONTROL.
IMPORTANT
!
!
Before proceeding with the electrical connections, ensure that the available electrical supply is compatible with
the voltage, frequency and phase listed on the appliance rating plate.
It is NOT permissible to connect unit to accessories such as humidifier transformers, condensate pumps and
electronic air cleaners.
ALL ELECTRICAL WORK MUST BE DONE BY A TRAINED, QUALIFIED TECHNICIAN. IMPROPER
MODIFICATIONS OR ADJUSTMENTS CAN RESULT IN FIRE OR EXPLOSION, CAUSING
PROPERTY DAMAGE, SEVERE PERSONAL INJURY OR LOSS OF LIFE.
WARNING
!
!
PROVIDE EACH CONDO PACK UNIT WITH ITS OWN SEPARATE ELECTRICAL CIRCUIT, MEANS
OF CIRCUIT PROTECTION, AND ELECTRICAL DISCONNECT SWITCH. FOLLOW CURRENT
NATIONAL ELECTRICAL CODE ANSI/NFPA 70, CSA C22.1 C.E.C. PART 1, AND STATE AND
LOCAL CODES. FAILURE TO PROVIDE THESE SHUT-OFF MEANS COULD CAUSE
ELECTRICAL SHOCK OR FIRE, RESULTING IN DAMAGE, INJURY OR DEATH.
WARNING
!
!
Summary of Contents for Condo Pack
Page 58: ...58 IOM IOM W415 2288 08 29 2019 9 3 P E HEATING MODULE...
Page 62: ...62 IOM IOM W415 2288 08 29 2019 44 1...
Page 63: ...63 IOM W415 2288 08 29 2019 44 1...
Page 122: ...58 IOM IOM W415 2288 08 29 19 9 3 MODULE DE CHAUFFAGE LECTRIQUE CONDO PACK P E...
Page 126: ...62 IOM IOM W415 2288 08 29 19 44 1...
Page 127: ...IOM W415 2288 08 29 19 44 1...