![Napoleon Condo Pack Installation And Operating Instructions Manual Download Page 19](http://html1.mh-extra.com/html/napoleon/condo-pack/condo-pack_installation-and-operating-instructions-manual_3307042019.webp)
19
IOM
W415-2288 / 08.29.2019
H68.3.5
8.
When installed, the Wall Sleeve
must
protrude
1/2” MIN. to 1” MAX
. beyond the exterior fi nished wall
to allow proper water evacuation through the drain holes
in the bottom panel. See FIG. 8.
INSTALLATION CREW MUST ADHERE TO ALL LOCAL/NATIONAL SAFE WORK PRACTICES
INCLUDING EMPLOYING APPROPRIATE FALL ARREST EQUIPMENT
WARNING
!
!
Flashing
Finished Wall
Wall Sleeve
Flashing
PROTRUDE
1/2” MIN.-1” MAX.
PROTRUDE
1/2” MIN.-1” MAX.
O U T S I D E
I N S I D E
8
9.
Wall sleeve can be installed from inside or outside the
building (FIG. 9). The side and top brackets’ position need
to be adjusted to suit the method and building material.
9
Install the wall
sleeve into the
wall until the
support brackets
are set on wall
edge.
H68.3.5
1.5”
5
416
“
10”
10”
Position B
Position A
10
7
7
7
2
2
3
3
3
4
4
4
4
11
6
1
1
1
7
7
10
5
4 16
“
5
4
16
“
11
5
5
11
10.
Attach the Side Support Brackets (5) to the Side
Panels (3) & (4) and to Base Panel with fi ve screws
(7) through the shorter fl ange (FIG. 10).
1.5”
5
416
“
10”
10”
Position B
Position A
10
7
7
7
2
2
3
3
3
4
4
4
4
11
6
1
1
1
7
7
10
5
4 16
“
5
4
16
“
11
5
5
10
11.
Select the set of mounting holes based on type of
construction wall face application (brick, stucco,
siding, etc.):
a. For Side Support Brackets (5), use pre-drilled
mounting Position A or Position B shown in FIG. 11,
depending on the type of wall construction.
b. Attach Top Support Bracket (6) to the Top Panel
(1) using minimum three screws (7) provided, (FIG.
11). For this bracket (6), use mounting Position A or
Position B shown in FIG. 11.
NOTE: The following support bracket locations are for
installations where the wall sleeve is installed from the
OUTSIDE of the building.
For installations where the wall sleeve is installed from the
INSIDE of the building, the Side Support Brackets (5) need
to be mounted on INTERIOR wall, so they will need to be
relocated on the wall sleeve (new screw positions may need
to be created depending of the type of wall construction).
NOTE:
When using wall sleeve size CWSMUA19
(not standard CWSMUA size), make sure to replace
the standard Top Panel bracket (W080-1384) with the
specially designed
top panel bracket (W080-1721)
in order to properly secure the cabinet to the wall sleeve
(FIG. 12).
W080-1721:
To be used with
CWSMUA19.
To be field
installed to
REPLACE factory
installed bracket.
W080 -1384:
STANDARD BRACKET
is factory installed
on cabinet.
12
Summary of Contents for Condo Pack
Page 58: ...58 IOM IOM W415 2288 08 29 2019 9 3 P E HEATING MODULE...
Page 62: ...62 IOM IOM W415 2288 08 29 2019 44 1...
Page 63: ...63 IOM W415 2288 08 29 2019 44 1...
Page 122: ...58 IOM IOM W415 2288 08 29 19 9 3 MODULE DE CHAUFFAGE LECTRIQUE CONDO PACK P E...
Page 126: ...62 IOM IOM W415 2288 08 29 19 44 1...
Page 127: ...IOM W415 2288 08 29 19 44 1...