3243h Digital Input Homing Capture
Function
With this object, the encoder position can be noted automatically if a level change occurs at the digital
input that is used for the home switch.
Object description
Index
3243
h
Object name
Digital Input Homing Capture
Object Code
ARRAY
Data type
UNSIGNED32
Savable
yes, category: application
Access
read only
PDO mapping
no
Allowed values
Preset value
Firmware version
FIR-v1738-B501312
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
04
h
Subindex
01
h
Name
Control
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000000
h