10 Description of the object dictionary
h
in the range from -1 to -100
The entered value is interpreted as a percentage and determines the reduction of the rated
current in 2037
h
. The value in 2031
is used for the calculation.
has the value 4200 mA. The value -60 in 2037
reduces the current by
60% of 2031
h
. The result is a current reduction to a root mean square of 2031
+ 100) /
100 = 1680 mA.
h
would, for example, mean that a current reduction is set to a root mean
square of 0 mA.
Note
If the rated current is greater than 0 in 203B
:01, the smaller of 2031
h
h
:01 is used as the
rated current for calculating the current reduction.
2038h Brake Controller Timing
Function
This object contains the times for the brake control in milliseconds as well as the PWM frequency and
the duty cycle.
Object description
Index
2038
h
Object name
Brake Controller Timing
Object Code
ARRAY
Data type
UNSIGNED32
Savable
yes, category: application
Firmware version
FIR-v1426
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
06
h
Subindex
01
h
Name
Close Brake Idle Time
Data type
UNSIGNED32
Access
read / write
PDO mapping
no
Version: 1.0.1 / FIR-v1748